STEP EXCITE: Service & maintenance manual - rev. 1.4
Figure 4.5-12
Figure 4.5-13
Figure 4.5-14
19. Remove the covering from the LED display,
backing off the 3 screws h using a medium
Phillips screwdriver.
20. Unplug the TGS cable, if present.
21. Assemble the covering removed previously
in step 19 onto the WTV display, and secure
using the 3 screws h.
22. Connect the following cables to the WTV
display:
• Cable 8 (STP_07) on connector j1 of the
connector board.
• All
the
disconnected from the display in step 3.
• The TGS cable, if present, on connector
CN8 of the CPU board.
23. Fix the new display on the machine using the
4 screws removed previously in step 2.
24. Affix the sticker 10 in the position indicated
in the figure.
25. Turn on the machine and check that it is
working properly.
26. Carry out the Wellness TV configuration and
tuning procedure.