Rotex HPSU Installation Manual

Rotex HPSU Installation Manual

Monobloc compact outdoor unit
Hide thumbs Also See for HPSU:

Advertisement

Quick Links

Installation manual
ROTEX HPSU monobloc compact outdoor unit
Installation manual
English
ROTEX HPSU monobloc compact outdoor unit

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPSU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rotex HPSU

  • Page 1 Installation manual ROTEX HPSU monobloc compact outdoor unit Installation manual English ROTEX HPSU monobloc compact outdoor unit...
  • Page 2 3P403988-7F...
  • Page 3: Table Of Contents

    ▪ Installer reference guide: Table of Contents ▪ Preparation of the installation, good practices, reference data,… ▪ Format: Digital files on the ROTEX homepage Latest revisions of the supplied documentation may be available on 1 About the documentation the regional ROTEX website or via your dealer.
  • Page 4: Preparation 4

    NOT installed on the unit, provide a minimum Power supply for 2+GND space of 250 mm. outdoor unit The maximum allowable distance between outdoor unit and HPSU Optional equipment monobloc tank is 10 m. Remote outdoor sensor 2 The outdoor unit is designed for outdoor installation only, and for Field-supplied components ambient temperatures ranging 10~43°C in cooling mode, –25~25°C...
  • Page 5: To Open The Switch Box Cover Of The Outdoor Unit

    In any case, provide at least 300  mm of free space below the unit. Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow. RBLQ05+07C2V3 Installation manual ROTEX HPSU monobloc compact outdoor unit 4P501825-1 – 2017.08...
  • Page 6: To Install The Outdoor Unit

    NOTICE Provide at least 300  mm of free space below the unit. Additionally, make sure the unit is positioned at least 100 mm above the expected level of snow. Installation manual RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501825-1 – 2017.08...
  • Page 7: To Prevent The Outdoor Unit From Falling Over

    2 Connect the field piping on the shut-off valves. 3 For how to connect the HPSU monobloc tank, see the In case the unit is installed in places where strong wind can tilt the installation manual of the tank.
  • Page 8: To Connect The Main Power Supply

    The distance between the high voltage and low voltage cables should be at least 25 mm. Routing Possible cables (depends on the installed options) ▪ Interconnection cable to HPSU monobloc tank Low voltage ▪ Remote outdoor sensor (option) ▪ Shut-off valve (field supply) High voltage ▪...
  • Page 9: Commissioning

    HPSU monobloc tank. legislation: ▪ Between the local supply panel and the outdoor unit ▪ Between the local supply panel and the HPSU Hand-over to the user monobloc tank ▪ Between the local supply panel and the optional...
  • Page 10: Technical Data

    Capillary tube 6.4 CuT 12.7 CuT 7.9 CuT Capillary tube 7.9 CuT 4.0 CuT 7.9 CuT 4.0 CuT Capillary tube 7.9 CuT Heat exchanger thermistor Propeller fan 3D097222-1 Installation manual RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501825-1 – 2017.08...
  • Page 11: Wiring Diagram: Outdoor Unit

    Connector X1M, X2M Terminal strip PCB3 Service PCB Electronic expansion valve coil # Shut-off valve Reversing solenoid valve coil XAG1 Terminal strip Z1C~Z4C Ferrite core Optional Field supply RBLQ05+07C2V3 Installation manual ROTEX HPSU monobloc compact outdoor unit 4P501825-1 – 2017.08...
  • Page 12 7 Technical data Electrical connection diagram Hydro switch box NO Valve XAG1 Power Supply Q3DI -t° 1N~, 50 Hz 230 V AC external outdoor ambient Power supply sensor option 4D112157A Installation manual RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501825-1 – 2017.08...
  • Page 16 Unsere Partner im Ausland Our partners abroad • Unsere Partner im Ausland Nos partenaires à l’étranger • Le nostre sedi all'estero Neustros representantes en el extranjero Nasi partnerzy za granicą • Naši partneři v zahraničí http://de.rotex-heating.com > ueber-rotex > international 4P501825-1 2017.08...

Table of Contents