  • Page 1 Installer reference guide ROTEX HPSU monobloc compact outdoor unit Installer reference guide English ROTEX HPSU monobloc compact outdoor unit...
  • Page 2 To insulate the water piping ........15 injury. Connecting the electrical wiring..........15 6.5.1 About connecting the electrical wiring......15 6.5.2 Precautions when connecting the electrical wiring ..15 Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 3: For The Installer

    ▪ In places where there is machinery that emits electromagnetic comply with applicable legislation (on top of the waves. Electromagnetic waves may disturb the control system, instructions described in the ROTEX documentation). and cause malfunction of the equipment. CAUTION ▪ In places where there is a risk of fire due to the leakage of...
  • Page 4: Brine

    If NOT factory installed, a main switch or other means for disconnection, having a contact separation in all poles providing full disconnection under overvoltage category  III condition, MUST be installed in the fixed wiring. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 5: About This Document

    ▪ Preparation of the installation, good practices, reference data,… ▪ When installing the earth leakage protector, make sure ▪ Format: Digital files on the ROTEX homepage it is compatible with the inverter (resistant to high Latest revisions of the supplied documentation may be available on frequency electric noise) to avoid unnecessary opening the regional ROTEX website or via your dealer.
  • Page 6: Outdoor Unit

    NOTICE 1 Open the outdoor unit. When installing or servicing several units at the same time, make sure NOT to switch the service panels between different models. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 7: Identification Label: Outdoor Unit

    Air outlet Do NOT install the unit in the following places: ▪ Sound sensitive areas (e.g. near a bedroom), so that the operation noise will cause no trouble. RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 8: Additional Installation Site Requirements Of The Outdoor Unit In Cold Climates

    ▪ Use a decent thread sealant to seal connections. NOTICE If glycol is present in the system, make sure the thread sealant used is resistant to glycol. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 9: Formula To Calculate The Expansion Vessel Pre Pressure

    ▪ Hygienic measures. The installation must be in compliance with the applicable legislation and may require additional hygienic installation measures. RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 10: Changing The Pre-Pressure Of The Expansion Vessel

    ▪ The required pre-pressure is: Pg = (0.3+(H/10)) bar = (0.3+(0/10)) bar=0.3 bar. ▪ The corresponding maximum water volume at 0.3  bar is 150  l. (See the graph in the chapter above). Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 11: Preparing Electrical Wiring

    The following illustration is an example and might NOT is removed. match your system layout. 6.2.2 To open the outdoor unit DANGER: RISK OF ELECTROCUTION Outdoor unit DANGER: RISK OF BURNING HPSU monobloc tank RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 12: To Open The Switch Box Cover Of The Outdoor Unit

    Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise. Fix the unit securely by means of foundation bolts in accordance with the foundation drawing. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 13: To Install The Outdoor Unit

    3 Remove the protective cardboard and instruction sheet. Protective cardboard Instruction sheet 6.3.4 To install the outdoor unit CAUTION Do NOT remove the protective cardboard before the unit is installed properly. RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 14: To Provide Drainage

    Mind their position: the integrated drain valves will only 3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cable from scratching the paint (field supply). Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 15: To Insulate The Water Piping

    6.5.1 About connecting the electrical wiring a Curled single-core wire Before connecting the electrical wiring b Screw Make sure the water piping is connected. c Flat washer RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 16: To Connect The Electrical Wiring On The Outdoor Unit

    When installing field supply or option cables, foresee sufficient cable length. This will make it possible to remove/ reposition the switch box and gain access to other components during service. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 17: To Connect The Remote Outdoor Sensor

    There are NO loose connections or damaged electrical components in the switch box. There are NO damaged components or squeezed pipes on the inside of the outdoor unit. RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 18: Maintenance Safety Precautions

    ▪ open the valve until the discharged water does NOT contain dirt anymore ▪ flush the system and install an additional water filter (a magnetic cyclone filter is preferable). Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 19: Overview: Troubleshooting

    Self-combustion and explosion of the compressor because of air going into the operating compressor. ▪ Use a separate recovery system so that the unit's compressor does NOT have to operate. RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 20: Piping Diagram: Outdoor Unit

    Capillary tube 6.4 CuT 12.7 CuT 7.9 CuT Capillary tube 7.9 CuT 4.0 CuT 7.9 CuT 4.0 CuT Capillary tube 7.9 CuT Heat exchanger thermistor Propeller fan 3D097222-1 Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 21: Wiring Diagram: Outdoor Unit

    X1M, X2M Terminal strip PCB3 Service PCB Electronic expansion valve coil # Shut-off valve Reversing solenoid valve coil XAG1 Terminal strip Z1C~Z4C Ferrite core Optional Field supply RBLQ05+07C2V3 Installer reference guide ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 22: Esp Curve: Outdoor Unit

    If glycol is added to the system, the operation range limit is lower. ▪ Selecting a flow outside the operating area can damage the unit or cause the unit to malfunction. Installer reference guide RBLQ05+07C2V3 ROTEX HPSU monobloc compact outdoor unit 4P501827-1 – 2017.08...
  • Page 23 Optional equipment Equipment made or approved by ROTEX that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by ROTEX that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 24 Unsere Partner im Ausland Our partners abroad • Unsere Partner im Ausland Nos partenaires à l’étranger • Le nostre sedi all'estero Neustros representantes en el extranjero Nasi partnerzy za granicą • Naši partneři v zahraničí http://de.rotex-heating.com > ueber-rotex > international 4P501827-1 2017.08...