SPECIFIC CONTROLS FOR ALIBI MEMORY (OPTIONAL)
Storage requests
Control
Response
where:
ss
c
w...w
uu
pp
t...t
xxxxx
yyyyyy
Examples
PIDST,1, 1500,0kg,PT
PIDUS,1, 1500,0kg,PT
Reading of a weighing in memory
Control
s , w w w w w w w w w w u u , p p t t t t t t t t t t u u<CR><LF>
Response
where:
s
w...w
uu
pp
t...t
Examples
ALRD00000-000158<CR><LF>
1, 1500,0kg,
nnPID<CR><LF> request to store the weight
recording successful
nnPIDss,c,wwwwwwwwwwuu,ppttttttttttuu,xxxxx-yyyyyy<CR><LF>
no recording
nnPIDss,c,wwwwwwwwwwuu,ppttttttttttuu,NO<CR><LF>
status of weight (2 characters)
TL
Error of condition of  (NO RECORDING)
OL
Condition of oveoa (NO RECORDING)
UL
Condition of eoa (NO RECORDING)
ST
Weight stable
US
Weight unstable (NO RECORDING)
Scale number (1 character)
Gross weight (10 characters)
Unit of measurement (2 characters)
Type of tare: double space " " if semi-automatic, "PT" if pre-set (2 characters)
Tare value (10 characters)
Number of rewriting (5 characters)
Progressive weighted (6 characters)
2,8kg,00000-000158<CR><LF>
2,8kg,NO<CR><LF>
nnALRDxxxxx-yyyyyy<CR><LF>
Where xxxxx is the rewriting number, yyyyyy is the progressive weighted.
Number of scales (always 1)
Gross weight (10 characters)
Unit of measurement ("g", "kg", " t", "lb")
Type of tare: double space " " if semi-automatic, "PT" if pre-set (2 characters)
Tare value (10 characters)
2,8kg<CR><LF>