Full Up Position and Full Down Position Calibrations
The Power Sensor must have valid Zero G Calibration before you do the Full Up Position and Full Down Position calibrations.
Zero G Calibration is done at the factory. To inspect the Zero G Calibration status, look at the 0G sub-submenu option and make
sure that the Progress Status shows "PASS".
When you do the Full Up Position and Full Down Position calibrations, the sequence is not important.
NOTICE: The Power Sensor must be installed on the bike for the Full Up Position calibration and the Full Down Position
calibration. Refer to the Schwinn® MPower™ Power Upgrade Installation Guide.
• • •
If the Power Sensor is not installed on the bike, install it on the bike. Refer to the Schwinn® MPower™ Power Upgrade
Installation Guide.
• • •
Tap the AVG/END or STAGE button to look at the Stage options.
Full Up Position:
Full Down Position:
• • •
Tap the AVG/END or STAGE button to go to the UP (Stage 1) option.
• • •
Push the Backlight button to make your selection.
• • •
Turn the Brake Adjustment Knob to the farthest left position (–) to raise the Brake
Carriage to the Full Up Position.
• • •
After the Brake Carriage is stable for 3–4 seconds, push the Backlight button.
• • •
The timer starts to count down.
• • •
Look for the result from the Power Sensor on the console display. The message
"PASS" shows if the calibration result is satisfactory. The message "FAIL" shows if
the timer counted down to zero and the calibration result is unsatisfactory.
• • •
Tap the AVG/END or STAGE button to go to the dn (Stage 2) option.
• • •
Push the Backlight button to make your selection.
• • •
Turn the Brake Adjustment Knob to the farthest right position (+) to lower the Brake
Carriage to the Full Down Position.
• • •
Push the Backlight button.
• • •
The timer starts to count down.
• • •
Look for the result from the Power Sensor on the console display. The message
"PASS" shows if the calibration result is satisfactory. The message "FAIL" shows if
the timer counted down to zero and the calibration result is unsatisfactory.