Before beginning any alignment procedure, make sure driver power is locked out.
WARNING
Failure to lock out driver power will result in serious physical injury.
Piping:
Never draw piping into place by forcing at the flanged connections of the pump.
CAUTION
This may impose dangerous strains on the unit and cause misalignment between
pump and driver. Pipe strain will adversely effect the operation of the pump
resulting in physical injury and damage to the equipment.
Flanged Connections:
WARNING
Use only fasteners of the proper size and material.
Replace all corroded fasteners.
WARNING
Ensure all fasteners are properly tightened and there are no missing fasteners.
WARNING
Startup and Operation:
WARNING
When installing in a potentially explosive environment, please ensure that the
motor is properly certified.
Operating pump in reverse rotation may result in contact of metal parts, heat
WARNING
generation, and breach of containment.
WARNING
Lock out driver power to prevent accidental start-up and physical injury.
The impeller clearance setting procedure must be followed. Improperly setting
WARNING
the clearance or not following any of the proper procedures can result in sparks,
unexpected heat generation and equipment damage.
If using a cartridge mechanical seal, the centering clips must be installed and set
WARNING
screws loosened prior to setting impeller clearance. Failure to do so could result
in sparks, heat generation, and mechanical seal damage.
The coupling used in an ATEX classified environment must be properly certified
WARNING
and must be constructed from a non-sparking material.
Never operate a pump without coupling guard properly installed. Personal injury
WARNING
will occur if pump is run without coupling guard.
Make sure to properly lubricate the bearings. Failure to do so may result in excess
WARNING
heat generation, sparks, and / or premature failure.
The mechanical seal used in an ATEX classified environment must be properly
certified. Prior to start up, ensure all points of potential leakage of process fluid to
CAUTION
the work environment are closed.
Never operate the pump without liquid supplied to mechanical seal. Running a
CAUTION
mechanical seal dry, even for a few seconds, can cause seal damage and must be
avoided. Physical injury can occur if mechanical seal fails.
Never attempt to replace packing until the driver is properly locked out and the
WARNING
coupling spacer is removed.
WARNING
Dynamic seals are not allowed in an ATEX classified environment.
DO NOT operate pump below minimum rated flows or with suction and/or
discharge valve closed. These conditions may create an explosive hazard due to
WARNING
vaporization of pumpage and can quickly lead to pump failure and physical injury.
General Precautions