Set-Up (Authorised Staff Only); Contents Of Display - Smeg UD505DAUS Translation Of The Original Instructions

Table of Contents

Advertisement

Using the buttons
Button
Display temperatures
Boiler and tank
Scroll through Setup
options (2)
Set Short Programme Start Short Programme
Set Medium
Programme
Set Long Programme Start Long Programme
Set P0 (Empty tank)
1) Restores the default parameters.
A series of operations can be carried out when the dishwasher is first installed to customise it to the user's
requirements.

7.1 SET-UP (Authorised staff only)

Set-up
During first start-up, the functions/parameters listed below must be set or adjusted:

7.2 Contents of display

The display provides the following information:
• Machine off but energized: OFF
• Machine on and ready for use: End/P1-P2-OP3
• Wash phase: ||||||||||
• Programming phase: See parameter programming section
• Error message: See error messages section
Note on display of temperatures
Temperatures shown on the display might not indicate the actual temperature in the tank and/or boiler
during heating - wait about 1' after the heating elements switch off to see the real temperature.
Short press
On/OF
Start Medium
Programme
Peristaltic pumps in
Manual mode to prime
pipes
Pressed for 2"
Pressed for 5"
Start Pump-
out
Start P0
Door closed
15
Long press, release, press
again
Door open and machine
OFF.
Long press >>> display
reads "- -" >>> release
and press again: Access
Setup Menu (1)
Total pump-out
(tank+boiler)
Reset to DEFAULT
parameters (1)
Technician user only