The following safety information must be 1. SAFETY INFORMATION SAFETY observed to insure maximum personal safety SYMBOLS during the operation of this meter. Warning ! Dangerous Voltage (Risk 1.1 Do not operate the meter if the body of electric shock). meter or the test lead look broken.
METER DESCRIPTION D. HOLD Terminals Light > 2 Sec Refer to table 1 for terminal function 400A~ 3000A~ Terminal Function Common terminal for all measurement Volts, Ohm, Diode, Freq., Temp. V/Ù/Hz Ù and Cap. Measurement and square wave output terminal Table 1.
Set up reference value for your measurement. Pressing this button for more than 1 seconds, select your measurement function and your the meter exits the HOLD mode and returns range. to the normal state. Press SET once, then press SELECT twice to Pressing the button for more than 2 seconds select the reference value for a measurement.
Express Function : 2. Clamp Light easy for test the electric current in poorly lighted places. 1. Display : LCD Dual Display, facilitates to read the data.
Page 7
3. Leads Cramp in the clamp Easy for fixing 4. Magnet the meter back for fixing one Lead when need test two instruments on metal shelves, Measured separation vertices. convenient operation.
Operating environment : 5. The distributing line device will avoid the dangerous when distributing electrical wire Temperature 32 to 104°F (0°C to 40°C), with hands. Humidity < 80% RH. Storage environment : Temperature -4 to 140°F (-20 °C to 60°C), Humidity >...
2.2.3 DC Current Range Accuracy Resolution 400A ±(3.0% of rdg+10digits) 0.1A ±(3.5% of rdg+20digits) 0-1000 1000-2000 ±(5.5% of rdg+20digits) 3000A ±(6.5% of rdg+40digits) 2000-3000 Overload protection : 3000A DC or AC rms 2.2.4 AC Current (True RMS) Accuracy Range Resolution 50-500Hz 500-1KHz ±(3.5% of rdg...
3.3 AC Current Measurement 3.6 Diode And Audible continuity Test 1) Connect the black test lead to “COM” socket and 1) Set the selector switch to desired “400A~” or “3000A~” position. red test lead to the “VÙHz” socket. 2) Press “SELECT”...
3.9 Data Hold 4. MAINTENANCE On any range, press the “D. HOLD” key to lock 1) Before open the battery door, disconnect display value, and the “HOLD” sign will appear on both test lead and never use the meter the display, press it again to exit. before the battery door is closed.
The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. 860 A MODEL NO. ___________ SERIAL NO. ___________ DATE: ___________ ISO 9001 KUSAM-MECO REGISTERED PASS...