3 3/4 digits ac/dc autoranging digital clampmeter

Advertisement

An ISO 9001:2008 Company
SPECIAL FEATURES :
High Resolution DCA / ACA of 1mA
Auto Polarity display
Auto Zero Adjustment
Display annunciators for all functions & ranges
Continuity & Diode Measurements
Auto Power Off
Low Battery Indication
GENERAL SPECIFICATIONS :
Sensing : Average sensing
Jaw Size : 23 mm
Display : 3¾ digits 4000 counts LCD display
Sampling rate : 2.5 reading / sec.
Low Battery : "
" mark is displayed when
the Battery Voltage drops below 2.4V
Over range indication : Display "OL" or "-OL"
ACCESSORIES :
Test leads, Carrying Case, Battery installed, User's Manual
AC/DC CURRENT (Model KM 2720)
Range
Accuracy (ACA)
Resolution
±(2.0%rdg + 3dgts)
40 A
10 mA
±(2.5%rdg + 3dgts)
200 A
100 mA
AC VOLTAGE
Range
Resolution
±(1.8%rdg + 5dgts)
400 mV
100
V
±(1.0%rdg + 3dgts)
4
V
1
mV
±(1.0%rdg + 3dgts)
40
V
10 mV
±(1.0%rdg + 3dgts)
400
V
100 mV
±(1.5%rdg + 3dgts)
750
V
1
V
Input Impedance : 10M
AC Voltage Test Frequency : 50Hz~500Hz for 400V & below,
& 50Hz~100Hz for above 400V.
Overload Protection : DC 1000V or AC 750V rms
RESISTANCE
Range
Resolution
±(1.0%rdg + 2dgts)
400
100 m
±(1.0%rdg + 2dgts)
4
k
1
40
k
10
±(1.0%rdg + 2dgts)
±(1.0%rdg + 2dgts)
400 k
100
±(1.0%rdg + 2dgts)
4
M
1
k
±(1.5%rdg + 2dgts)
40 M
10
k
Overload Protection : 250V rms
®
An ISO 9001:2008 Company
Chhaya Computer/D:/Chhaya/Coreldraw Files/New catlogs Dec 2011/KM 2720-KM 2725.cdr
®
3¾ DIGITS AC/DC AUTORANGING
Operating Temperature : 0°C~50°C;
Storage Temperature : -20°C to 60°C; 80% R.H.
(Without battery)
Power Supply : 1.5V AAA battery x 2
Dimension : 183(L) X 43(W) X 31(H) mm
Weight : Approx. 200 gm (battery included)
ELECTRICAL SPECIFICATIONS- KM2720 / KM2725
Accuracy is ± (% reading digits + number of digits ) or otherwise specified, at 23°C ± 5°C & less than 75% R.H.
Accuracy (DCA)
±(2.0%rdg + 2dgts)
±(2.5%rdg + 2dgts)
DC VOLTAGE
Accuracy
Range
400 mV
4
V
40
V
400
V
1000
V
Input Impedance : 10M
Overload Protection : DC 1000V or AC 750V rms
CONTINUITY TEST
Range
Accuracy
DIODE TEST
Range
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022 -24156638,
Email : kusam_meco@vsnl.net,
DIGITAL CLAMPMETER
Model - KM 2720 - 17 FUNCTIONS 27 RANGES
KM 2725 - 17 FUNCTIONS 27 RANGES
75% R.H.
AC/DC CURRENT (Model KM 2725)
Range
Resolution
4
A
40 A
Accuracy
Resolution
±(1.0%rdg + 2dgts)
100
V
±(0.8%rdg + 2dgts)
1
mV
±(0.8%rdg + 2dgts)
10 mV
±(0.8%rdg + 2dgts)
100 mV
±(0.8%rdg + 2dgts)
1
V
Description
If the resistance is less than
100 , the beeper sounds
continuously
Description
Display read approx. Forward
Voltage of diode.
Accuracy : ±(3.0%rdg + 3dgts)
All Specifications are subject to change without prior notice
Tel. : 022-241224540, 24181649,
KM2720
KM2725
Accuracy (ACA)
Accuracy (DCA)
±(3.0%rdg + 3dgts)
±(3.0%rdg + 2dgts)
1
mA
±(2.0%rdg + 3dgts)
±(2.0%rdg ± 2dgts)
10 mA
CAPACITANCE
Range
Accuracy
Resolution
10
pF
±(2.5%rdg + 10dgts)
40 nF
100 pF
±(2.0%rdg + 4dgts)
400 nF
4
F
±(2.0%rdg + 4dgts)
1
nF
40
F
±(2.5%rdg + 4dgts)
10
nF
Overload Protection : 250V rms
FREQUENCY
Range
Accuracy
Unspecified
9.999 Hz
±(0.2%rdg + 3dgts)
99.99 Hz ~ 9.999 MHz
Sensitivity : Frequency - 0.7V AC rms;
Voltage - 0.1V AC rms
Overload Protection : 250V rms
DUTY CYCLE
Range
Sensitivity
Resolution
Frequency - 0.7V AC rms
0.1%~99.9%
0.1%
Voltage - 0.1V AC rms
Overload Protection : 250V rms
Fax : 022 - 24149659
Website : www.kusamelectrical.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 2720 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kusam-meco KM 2720

  • Page 1 ® 3¾ DIGITS AC/DC AUTORANGING DIGITAL CLAMPMETER An ISO 9001:2008 Company Model - KM 2720 - 17 FUNCTIONS 27 RANGES SPECIAL FEATURES : High Resolution DCA / ACA of 1mA KM 2725 - 17 FUNCTIONS 27 RANGES Auto Polarity display Auto Zero Adjustment Display annunciators for all functions &...
  • Page 2 AC Clamp Adaptor AUTORANGING AC/DC Current Adaptor Transistorised Electronic Analog & Digital CLAMPMETER Insulation Resistance Testers KM 2720 / KM 2725 Digital Sound Level Meter & Sound Level Calibrator Digital contact & Non-contact Type Tachometer Digital Non-contact (infrared) Thermometer Thermo Hygrometer...
  • Page 3 EXCLUSIVE REMEDY AND IS IN LIEU OF ALL CLAMPMETER OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED KM 2720 / KM 2725 WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. “KUSAM-MECO” SHALL NOT BE LIABLE FOR...
  • Page 4 Even if you correctly insert your clamp meter in to the fuses, disposable batteries, carrying case, test circuit, you can still damage your meter. Don’t try to leads, or to any product which in “KUSAM-MECO’s” measure current in excess of your meter’s capacity. opinion, has been misused, altered, neglected, Check the current capacity of the Clamp meter first.
  • Page 5: Table Of Contents

    DC/AC Voltage Measurement Frequency & Duty Cycle Measurement SERIAL NO. ___________ Resistance Measurement Diode & Continuity Test Capacitance Measurement DATE: ___________ Auto Power Off Maintenance..........9 Battery Replacement....... 10 ISO 9001 Fuse Replacement........10 KUSAM-MECO REGISTERED Test Certificate........11 PASS Warranty..........13...
  • Page 6: Safety

    GENERAL INSTRUCTION 6.2 Battery Replacement The meter is powered by two 1.5V, R6 Um3 AA The KM 2720 / KM 2725 is a handhold digital clamp SIZE carbon zinc or alkaline battery, Replace battery if the low battery sign “...
  • Page 7: General Features

    6. Maintenance 2. GENERAL FEATURES WARNING Display : 3 ¾ digits LCD display with To avoid electrical shock or damage the meter’ 3999 counts. do not get water inside the case. If the meter Over range indication : Display “OL” or “-OL” fails to operate, check battery, test leads, fuse, Auto Function : Auto range, Auto power...
  • Page 8: Electrical Specifications

    Set the rotary switch to “CAP” position. ± 2.0%rdg ± 2d 0.01A Touch the probes to tested capacitor and get reading. AC VOLTAGE(Model KM 2720 & KM 2725) Connect the black test lead to “COM” terminal and red test lead to “V W” terminal. Range Resolution...
  • Page 9: Dc/Ac Voltage

    5.2 DC/AC Voltage Measurement DC VOLTAGE(Model KM 2720 & KM 2725) Set the rotary switch to “V” position. Press Range Resolution Accuracy REL/SELECT button to select DC or AC ± 1.0%rdg ± 2 400 mV 0.1 mV mode according to test voltage.
  • Page 10: Push Button

    CAPACITANCE (Model KM 2720 & KM 2725) 5.MEASUREMENT Range Resolution Accuracy 5.1DC/AC Current Measurement ± 2.5%rdg ±10d 100 pF ± 2.0%rdg ± 4d WARNING ± 2.0%rdg ± 4d To avoid damage to the meter or injury if the ± 2.5%rdg ± 4d...

This manual is also suitable for:

Km 2725

Table of Contents