Troubleshooting Guide - Ingersoll-Rand 2920B1 Operation And Maintenance Manual

Super duty impactools. 2920b series
Table of Contents

Advertisement

Trouble
Low power
Motor will not run
Tool will not impact
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
MAINTENANCE SECTION

TROUBLESHOOTING GUIDE

Probable Cause
Dirty Inlet Bushing or Air
Strainer Screen and/or Exhaust
Silencer
Worn or broken Vanes
Worn or broken Cylinder and/or
scored End Plates
Dirty motor parts
Improper positioning of Reverse
Valve
Incorrect assembly of motor
Insufficient lubricant in the
impact mechanism
Broken or worn impact
mechanism parts
Impact mechanism not assembled
correctly
23
Solution
Using a clean, suitable, cleaning solution, in a well
ventilated area, clean Air Strainer Screen, Inlet
Bushing and Exhaust Silencer.
Replace complete set of Vanes.
Examine Cylinder and replace it if it is worn or bro-
ken or if bore is scored or wavy. Replace End Plates
if they are scored.
Disassemble tool and clean all parts with a clean,
suitable, cleaning solution, in a well–ventilated area.
Reassemble tool as instructed in this manual.
Make certain that Reverse Valve is fully
engaged to the left or right.
Disassemble motor and replace worn or broken parts
and reassemble as instructed.
Remove Hammer Case Assembly and lubricate
impact mechanism.
Remove Hammer Case and examine impact
mechanism parts. Replace any worn or broken parts.
Refer to Assembly of the Impact Mechanism.