M017837080000 REV. January 19, 2011
H. Set High Speed on Time (Saturday and Sunday)
Press ENTER. Set desired "on" time for motor to
begin running on high speed. Use   keys to
navigate through each of the fields. The flashing field
is the active field. Using the
as desired for the high speed to turn on. Pressing
ENTER will finalize your selections.
I. Set High Speed off Time (Saturday and Sunday)
Set desired "off" time for motor to stop running on
high speed. Use   keys to navigate through
each of the fields. The flashing field is the active field.
Using the
keys, adjust the time as desired for
the high speed to turn off. Pressing ENTER will
finalize your selections.
High Speed override – Pressing the High Speed
Override button will set the motor on high speed for 60
minutes. In override mode, the LCD displays an illuminated
"Override" icon. Pressing High Speed Override button
again will exit override and your program settings will take
precedence.
Low Speed override – Pressing the Low Speed Override
button will set the motor on low speed for 60 minutes.
In override, the LCD displays an illuminated "Override"
icon. Pressing Low Speed Override button again will exit
override and your program settings will take precedence.
12
2EZ Speed
Pool Motor with Programmable Control/Timer
TM
keys adjust the time
Functions of The Enter Button:
1. Press to activate menu selection.
2. Press to confirm changes to each menu selection
(ENTER can be pressed to exit a menu selection
at any point if that setting is acceptable as is.
. After pressing to confirm changes, pressing
ENTER again will take you out of the MENU mode.
Three events will cause the motor to run or stop.
The rst event is a timer event. This type of event
occurs when the current system time matches one of the
programmed Time On or Time Off setting.
If the programmed time settings overlap, the following rules
are used to determine which setting takes precedent.
1. Time "On" takes precedence over Time "Off".
a. Example:
8 AM
10 AM
12 PM
Low On
High On
High Off
Low On
In the above example –
Low On 8 AM
High On 10 AM
High Off 12 PM
At 12 PM Transitions from High to Low
Low remains On until scheduled 7 PM Off time.
The above scenario works the same whether Low overlaps
with High, or High overlaps with Low.
2. Setting the "On" time and "Off" time to the same
value for one of the flow settings, will cause the
setting to be used continuously 24 hours a day.
a. Example Setting:
Low On: 8:00 AM
Low Off: 8:00 AM
. As the day changes from Friday to Saturday, the
settings for Saturday become effective immediately
at midnight. As the day changes from Sunday to
Monday, the settings for Monday become effective
immediately when the day changes at midnight.
7 PM
Low Off