Reference Conditions: 23°C ±5°C, 45 to 75% RH, 3V supply, conductor centered, earth's
magnetic field, no external magnetic or electrical field, sine wave 50/60Hz. Accuracy is
expressed as ± [% of reading (R) ± counts (cts)].
3.1

Electrical Specifications

AC Amperes
Range
400A
AC Volts (Auto-ranging)
Range Measurement
400V
0.5 to 399.9V
600V
Resistance - Ohms (Ω)
Range
400Ω
Continuity (
Range
6
1.800.561.8187

SPECIFICATIONS

Resolution
50 to 60Hz: 2% of R ± 5cts
0.1A
60 to 500Hz: 2.8% of R ± 5cts
Res.
0.1V
400 to 600V
1V
Measurement
Res.
0.3 to 399.9Ω
0.1Ω
)
Beeper
< 35Ω
www.
CHAPTER 3
Accuracy
Accuracy
50 to 60Hz:
1.0% of R ± 5cts
60 to 500Hz:
1.5% of R ± 5cts
Accuracy
1.9% of R
± 3cts
Test Voltage
1.5V
DC
.com
Overload
600Arms
Input
Overload
Impedance
600Vrms
1MΩ
Test Voltage Overload
1.5V
600Vrms
DC
Overload
600Vrms