Chapter 5. Shut-Offs And Circuit Breakers; Rcd/Elcb Outlet (Option); Main Circuit Breaker; Stabilisers - Snorkel MHP 15J Operator's Manual

Hide thumbs Also See for MHP 15J:
Table of Contents

Advertisement

RCD/ELCB Outlet (option)

Figure 5.1 - RED/ELCB Outlet
The RCD (Residual Current Device) is located at
the base and will protect against short circuits to
earth. When there is a short circuit the RCD will
shut down the 230v AC power to the platform out-
let.
To reset the outlet disconnect the power tool lead
from the platform box and reset the RCD at the
base.
If the problem persists call a trained service techni-
cian.

Main Circuit Breaker

Figure 5.2 - Main Circuit Breaker
There is only one circuit breaker, on a standard
MHP15J, that is accessible to the operator. Its pur-
pose is to protect the electrical circuits from electri-
cal overloads. When the circuit breaker trips (pops
out) push it back in then attempt to use the
MHP15J. If the circuit breaker trips a second time,
take the MHP15J out of service and refer the prob-
lem to a qualified trained service technician for re-
pair.
MHP15J – 11995A

Chapter 5. Shut-offs and Circuit Breakers

Stabilisers

The MHP15J cannot be raised unless the stabilisers
are lowered and the lift enable light on the lower con-
trol box is lit. Once the booms are raised from the
stowed position the stabilisers become disabled un-
til the booms are stowed in the travel position.
Figure 5.3 - Stabilisers
page 5 - 1