This Installation Guide will guide the installer through the process of installing and configuring a WyreStorm SW-0402-MV-HDMI or SW-0402-MV-HDBT Multi-View Scaler. Print out this page to use as a checklist for items required to install this WyreStorm device. WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features prior to starting the installation process.
2. Product Overview The WyreStorm SW-0402-MV-HDMI is a 4-input to 2-output scaling device that allows both analog and/or digital AV sources to be connected. Each of the four source input locations have three connection options: HDMI, VGA or YUV. Additionally, each analog input includes an audio input (stereo mini for VGA and RCA L/R for YUV) for embedding the video with an external audio source.
15-pin VGA cable is required. SW-0402-MV-HDMI: 2x HDMI Out19-pin type A HDMI female digital video/audio Video Outputs SW-0402-MV-HDBT: 1x HDMI Out19-pin type A HDMI female digital video/audio | 1x HDBT Out 8-pin RJ-45 female 5.5mm Male Barrel Jack Power In Connect to the included 12V DC 3A power supply.
It is acceptable to stack multiple products one atop of the other without a ventilation space between the units. However, WyreStorm recommends that if using more than two of this product, an empty space at least 1 rack unit (1.75 in) in height is used between every 2 chassis.
When connecting to an IR control system use the WyreStorm CAB-IR-LINK cable to remove the sleeve +5V DC. Visit the CAB-IR-LINK product page for details. 4.4 RS-232 Wiring The following wiring diagram shows the pinouts for the switcher. While not shown, connect the TX (transmit) to RX (receive) pin at the control system or PC side of the cable.
7.1 Management Suite Installation The WyreStorm Management Suite is an All-in-One tool that allows quick and easy access to all the WyreStorm configuration tools. With this tool software to configure Switchers, Matrixes, NetworkHD, and Enado is available under one interface. Bonjour is a requirement to use the Management Suite and must be installed before installing the Management Suite.
The scaler’s network connection can be configured to obtain an IP Address from a router using Dynamic Host Configuration Protocol (DHCP) or be set manually to a static IP Address. The scaler is configured for DHCP by default, WyreStorm recommends that a static IP is used to ensure that the IP Address to the scaler will not change.
WyreStorm recommends using a cable tester or connecting the cable to others devices to verify functionality. Contacting Technical Support Should further clarification of the content of this manual or assistance on troubleshooting be required, please contact WyreStorm technical support. Phone: North America: 844.280.WYRE (9973) | UK/EMEA: +44 (0) 1793 230 343 Email: Support@WyreStorm.com...
Obtaining Warranty Service Prior to returning a WyreStorm product for factory service, a service authorization must be obtained from a WyreStorm technical support representative. At the time of contact an address for shipping and an authorization number will be supplied. Refer to Contacting Technical Support for contact information.
WyreStorm reserves the right to change software, control codes and specifications without notice. WyreStorm will not be liable for any use of this information or any changes it may make to those products. The use of this information constitutes an agreement by the user to these limitations and exclusions.