Determining The Battery Condition - Datamax OC2 BT Technical Manual And User Manual

Direct thermal portable printer
Table of Contents

Advertisement

2. Plug the AC adapter power cord into an appropriate power
source.
3. Plug the AC adapter into the printer power port (Figure
16).
Power port
Figure16
4. Charge the battery. The battery status LED flashes red
while the battery is charging and turns solid green when
the battery is fully charged. One complete charge takes 4
to 5 hours.

Determining the battery condition

The battery voltage varies between 6.2 and 8.4 volts. While the
battery is powering the printer (AC adapter not connected), the
battery status LED displays the battery condition as follows:
: The battery is fully charged.
Solid Green
: The battery is partially discharged, but will
Solid Orange
power the printer. Plan on recharging the battery soon.
: The battery does not have sufficient charge to
Solid Red
operate the printer. Recharge it immediately.
For information on battery error conditions, see "Using the
control panel" on page 12.
Caution: There is a risk of explosion if the battery is
replaced by an incorrect type. Dispose of used
batteries according to the instructions.
Caution: The operating temperature of this portable printer is
50° C. However, the operating temperature when used with
Datamax-O'Neil power supply for charging the portable printer is
S
ETTING UP YOUR PRINTER
Battery status
Figure17
5