Operating Environment
Locate the printer in a convenient location meeting the requirements specified in this document. The
printer is designed for indoor use only. To ensure optimum performance, it is important that the printer
must be installed in a clean, dry, air-conditioned room. Avoid placing the printer in any environment
with airborne contaminants, including cigarette smoke, fumes, and mechanical particulates that can
adversely affect the long term functioning of this equipment.

Air Conditioning

A number of the ProJet® MJP 5600 System's internal electronic components as well as the part
material, are sensitive both to ambient temperature and, to some extent, humidity. In addition, the
build process itself can be temperature-sensitive within certain limits. The operating temperature range
should be between 18-28°C (64-82°F); optimal operational environment is 21-24°C (70-75°F).
Humidity
Humidity should be maintained at a minimum 30% and a maximum 70% relative humidity. Optimal is
35-45% relative humidity.
Lighting
The printer is equipped with its own internal light build chamber, and back lit operating panel control
with display.
Vibration and Shock
The printer consists of many precision mechanical and sensing systems that are sensitive to vibration
during the build process. To maximize the quality and accuracy of the build, it is required that the unit
not be near heavy machinery or any source causing high vibration or shock (i.e. exterior walls near
train tracks or airports).
NOTE: The printer MUST be placed on a vibration free concrete floor. Do not install on
any other floor covering such as vinyl, tile, carpeting, etc.. Doing so WILL affect
machine performance.
Elevation
Elevation up to 2000 meters ( 6561 feet).