Î Operate the utility
Î-1 Initializing the
setting data
UTILITY SOFTWARE
The procedures for operating the [AP-3 Utility] screen
are explained below. Encircled numbers refer to the
reference numbers shown in the screen shot on page
68.
[EXTREMELY IMPORTANT]
Never turn off the power to the AP-3 unit while it is
restarting after initializing the user data (setting
data) or updating the firmware (
If the power is turned off before the restart process
is completed, the data in the AP-3 unit will be lost
and the AP-3 will no longer function.
After "Processing completed. Restarting system..." is
displayed in area u of the [AP-3 Utility] screen, wait
until the lamps on the front panel return to the state they
were in before the restart process began.
[Scope of initialization]
When the initialization is executed from the Utility, all set-
ting data are initialized.
[Procedure]
1. Enter the IP address of the AP-3 unit in the [AP-3 IP
Address q] text box.
2. Click the radio button next to [Initialize User Data]
under [Function w].
3. Click the <Execute t> button.
• The status of the initialization is indicated in the area
u at the bottom of the screen. During restart, all front
panel lamps will be illuminated. When restart is com-
pleted, the lamps will return to their original state (i.e.,
how they were before the initialization was executed).
* The message "AP-3 not found" will be displayed if
communication between the setting terminal and the
AP-3 unit fails. Check the following:
• Is the AP-3 unit in [Update Mode] ( p. 68)?
• Did you enter the correct AP-3 IP address (
into the [AP-3 IP Address q] textbox?
4. Close the Utility.
p. 70 and 71).
(default value: 192.168.0.1)
12
p. 42)
69

Advertisement