DoAll C-8056SA Instruction Manual page 10

Metal cutting band sawing machine
Table of Contents

Advertisement

3.2 FOUNDATION REQUIRED
The thickness should be over 200mm. The foundation work must comply with local
regulations of construction. It is not suggested to install the machine in an upstairs area.
3.3 INSTALLATION ENVIRONMENT
※ Do not install the machine or controller at a location with direct sunlight and keep
the machine free from pollution of chips, water or oil from other machines.
※ The machine installation location should be free of vibration. Do not install the
machine in an area where there may be potential danger of explosion.
3.4 POWER SOURCE REQUIRED
Do not connect the machine to a power source with serious power interference caused
by welding machines or electric discharge machines. Keep the power source from
being affected by other machines. Avoid voltage drop resulting from insufficient power
capacity of the factory. Connect the machine to an independent power source.
C-8056 SA Input power: 12 KW
* Allowable input power tolerance: local voltage ±10%
3.5 GROUNDING
3.5.1 Do not use a grounding wire together with that of electric welding machines or electric
discharge machines.
3.5.2 Use a short and big grounding wire as possible.
3.5.3 Connect the grounding wire independently. Make sure the machine has been properly
grounded.