4.1.3 Detection of Silence

The call is disconnected after silence is detected on both call directions
for a specific (configurable) amount of time. This method should only be
used as a backup.
Display the Navigation Tree in Full View. Enable the relevant
detection method in Configuration tab > Protocol Configuration
menu > SIP Advanced Parameters submenu > Advanced
Parameters page item.

4.1.4 Timeout of Conversation

As an additional safety to prevent lines from accidentally locking up, it is
recommended to enable a timeout of conversation.
The 'Max Call Duration' defines the maximum call duration in minutes. If
this time expires, both sides of the call are released (IP and Tel). The
valid range is 0 to 120. The default is 0 (no limitation).
Display the Navigation Tree in Full View. Enable the 'Max Call
Duration' in Configuration tab > Protocol Configuration menu >
SIP Advanced Parameters submenu > Advanced Parameters
page item.