FUTABA 4PLS Manual page 53

2.4ghz t-fhss radio system
Hide thumbs Also See for 4PLS:

Advertisement

2
(Recording cycle setting)
Select the "CYCL" setting item by (JOG) but-
ton up or down operation, and set the data ac-
quisition interval from a minimum 0.1 second
to a maximum 60 seconds with the (+) button
or (-) button.
The maximum recordable time set by CYCL is
displayed at END TIME shown below.
3
(Count alarm ON/OFF)
Select the "ALRM" setting item by (JOG)
button up or down operation. To sound an
electronic beep at each log count, set "ALRM"
to ON with the (+) button or (-) button.
"OFF" : Alarm OFF
"ON"
: Alarm ON at each log count
When ending, move the cursor to [RT] by the (JOG) button,
and return to the HOME screen by pressing the (JOG) but-
ton twice.
Log function start/stop operation
1
(Log start operation)
-Start by switch (SW1)
When the switch (SW1) set by SW/dial func-
tion (p.65) is pressed, data logging starts.
-Starting by throttle trigger
Display the log setting (LOG MODE) screen
and select the "STATE" setting item by (JOG)
button up or down operation, and press the
(JOG) button for approximately 1 second.
An electronic beeping sound is generated and the "STATE" display switches from "RST"
to blinking "RDY", and the logger enters the trigger operation wait state. When the trig-
ger is operated in the forward direction, data logging begins. (STATE display "STA")
When the end time arrives, an electronic beep sounds and data logging stops. To return
to the HOME screen during data logging, move the cursor to [RT] by (JOG) button up or
down operation, and press the (JOG) button or (+) button.
2
(Log forced end)
To abort logging, press the switch (SW1), the same as starting, or display the log setting
(LOG MODE) screen and select the "STATE" setting item by (JOG) button up or down
operation and press the (JOG) button for approximately 1 second. An electronic beeping
sound is generated and logging is stopped.
4PLS-Eng-08-3-Function-P84-114.indd
Telemetry "TELEMETRY"
113
Log recording cycle
0.1~60s(
)
sec
0.1~10s(
)0.1s step
sec
10s~60s(sec)1s step
Initial value: 1.0
sec
Adjust button
- Adjust with the (+) and (-) but-
tons.
- Return to the initial value "0" by
pressing the (+) and (-) buttons
simultaneously for about 1 sec-
ond.
Log recording time
20s (seconds) 3h 20m (3 hours
20 minutes)
The maximum recordable time
set by CYCL is displayed auto-
matically.
Alarm ON/OFF
ON, OFF
- Select with the (+) or (-) but-
tons.
Status display
RDY :Throttle trigger operation wait
STA :Logger running
STP : Logger stopped
2013/04/08
113
9:10:33