Download Print this page

Installation - Mitsubishi Electric MELSEC-F FX2NC-1HC User Manual

Hide thumbs Also See for MELSEC-F FX2NC-1HC:

Advertisement

JY997D30701C
FX
-1HC
2NC
USER'S MANUAL
Manual Number
JY997D30701
Revision
C
Date
April 2015
This manual describes the part names, dimensions, mounting, wiring, and
specifications of the product. Before use, read this manual and the manuals of all
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective April 2015
Specifications are subject to change without notice.
©
2007 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
Series
JY997D28701
3UC
Explains the FX
Series PLC
3UC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R519
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/
FX
3UC
Series
JY997D16601
Describes PLC programming for
Programming Manual
MODEL CODE:
basic/applied instructions and
devices.
- Basic & Applied
09R517
Instruction Edition
Explains the FX
(DSS/DS)
2NC
JY992D76401
FX
(DSS/DS) Series
2NC
Series PLC specifications for I/O,
MODEL CODE:
Hardware Manual
wiring, installation, and
09R509
maintenance.
Explains the FX
2NC
(D/UL) Series
(D/UL) Series
FX
2NC
JY992D87201
PLC specifications for I/O, wiring,
Hardware Manual
installation, and maintenance.
Describes FX
1S
/FX
1N
JY992D88101
FX Series
FX
Series PLC programming
2NC
MODEL CODE:
Programming Manual II
for basic/applied instructions and
09R512
devices.
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
WIRING
PRECAUTIONS
• Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit or high-voltage lines.
2) Ground the shield wire or shield of the shielded cable at one point on the
PLC. However, do not use common grounding with heavy electrical
systems.
• Make sure to properly wire to the terminal board (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimensions described
in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires
of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected
parts are directly stressed.
3.1 Wire and Terminal Tightening Torque
3.1.1
Cable
1) Applicable cable
Wire size
Type
Single wire
2
2
0.3mm
to 0.5mm
(AWG22 to 20)
2
Double wire
0.3mm
(AWG22)*2
2) Termination
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it. An alternative
connection is to use a ferrule with insulating sleeve.
Manufacturer
Model
Pressure bonding tool
CRIMPFOX 6
Phoenix Contact
AI 0.5-8WH
(or CRIMPFOX 6T-F
*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6
• Stranded wire/solid wire
• Bar terminal with insulating sleeve
Insulating sleeve
Contact area
Termination of
(Crimp area)
cable end
9mm
(0.36")
8mm
(0.32")
2.6mm
14mm(0.56")
(0.11")
When using a stick terminal with an insulating sleeve, choose a wire with
proper cable sheath referring to the above outside dimensions, otherwise the
wire cannot be inserted easily.
3.1.2
Tightening Torque
The tightening torque must be 0.22 to 0.25N
m. Do not tighten terminal screws
exceeding the specified torque. Failure to do so may cause equipment failures or
malfunctions.
Tool
To tighten terminals, use a purchased
small-sized screwdriver whose head is
straight and is not widened as shown in
the right figure.
0.4mm
2.5mm
Note:
(0.02")
If the diameter of screwdriver grip is too
small, tightening torque will not be able
to be achieved. Use the following recommended screwdriver or an appropriate
replacement (grip diameter: approximately 25mm).
Manufacturer
Model
×
Phoenix Contact
SZS 0.4
2.5
3.2 Wiring
Note;
Make sure to properly wire in accordance with the encoder output specifications.
Incorrect wiring may cause accidents or damage to the product.
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Models:
MELSEC FX
series manufactured
2NC
from December 1st, 2007
FX
-1HC
2NC
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when
used as directed by the appropriate documentation.
Attention
• This product is designed for use in industrial applications.
Note
• Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
2NC
series manufactured
from December 1st, 2007
FX
-1HC
2NC
Standard
EN61000-6-4:2007
Compliance with all relevant aspects of
Electromagnetic compatibility
the standard. (Radiated Emissions and
- Generic standards - Emission
Mains Terminal Voltage Emissions)
standard for Industrial environment
EN61000-6-2:2005
Compliance with all relevant aspects of
Electromagnetic compatibility
t h e s t a n d a r d . ( R F I m m u n i t y, F a s t
- Generic immunity standard Industrial
Transients, ESD, Conducted, Surges,
environment
Power Magnetic Fields, Voltage dips and
Voltage interruptions)
EN61131-2:2007
Compliance with all relevant aspects of
Programmable controllers
the standard.
- Equipment requirements and tests
EMI
• Radiated Emissions
may
• Conducted Emissions
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
1. Outline
The hardware high-speed counter block is a 2-phase 50 kHz high-speed counter. It is a
special function block for the FX
, FX
series PLC.
2NC
3UC
• FROM/TO instruction transfers the PLC data (i.e. parameters, comparing value and
present value).
• The FX
occupies 8 points of I/O on the FX
2NC-1HC
8 points can be allocated from either inputs or outputs.
However, 5V DC 90mA power is supplied from the main unit or extension power
supply units. There must be no power overload from this or any other extension unit.
Furthermore, another power supply is needed for the output circuit of the encoder or
the transistor.
• Differential-Line-Driver (AM26C31 or equivalent) and open collector output
encoders are available for FX
-1HC.
2NC
• The source of your input signal should be a 1 or 2 phase encoder. A 5V, 12V, or 24V
/FX
2N
/
power source can be used. An initial value setting command input (PRESET) and a
count prohibit command input (DISABLE) are also available.
• The FX
has two outputs. When the counter value coincides with an output
2NC-1HC
compare value, the appropriate output is set ON. The output transistors are
individually isolated to allow either sink or source connection methods.
• Various counter modes, such as 1-phase or 2-phase, 16-bit or 32-bit modes, can be
selected using commands from the PLC. Allow the FX
setting these mode parameters.
3.2.1
NPN output encoders
FX
2NC
FX
3UC
DC24V
*2
FX
-1HC
Class D
2NC
3.3k
*1
A24+
1.5k
Shielded
Twisted-Pair
A12+
0.27k
A 5+
0.1k
A -
3.3k
*1
B24+
1.5k
B12+
0.27k
B 5+
0.1k
B -
1.5k
*1
XD24
0.5k
XD 5
0.2k
COMD
1.5k
*1
XP24
0.5k
XP 5
0.2k
COMP
Shielded
Twisted-Pair
*1. Drive power supply of the encoder.
Use either 24V DC, 12V DC, or 5V DC according to the encoder type.
When connecting the A phase, the B phase, and the Z phase to FX
connect to the power supply terminal.
When using 24V DC for PRESET and DISABLE signals, connect to the 24V
DC (XP24, XD24) terminal.
*2. Grounding resistance 100 Ω or less.
*3. This wiring is unnecessary when not using the PRESET function and the
DISABLE function.
3.2.2
PNP output encoders
*1
*2
)
DC24V
FX
2NC
FX
3UC
*2
Class D
FX
-1HC
2NC
3.3k
*1
A24+
1.5k
A12+
0.27k
A 5+
0.1k
A -
3.3k
B24+
*1
1.5k
B12+
0.27k
B 5+
Shielded
0.1k
Twisted-Pair
B -
DISABLE
1.5k
*1
XD24
0.5k
With
XD 5
straight tip
0.2k
COMD
PRESET
1.5k
*1
XP24
(0.1")
0.5k
XP 5
0.2k
COMP
Shielded
Twisted-Pair
*1. Drive power supply of the encoder.
Use either 24V DC, 12V DC, or 5V DC according to the encoder type.
When connecting the A phase, the B phase, and the Z phase to FX
connect to the power supply terminal.
When using 24V DC for PRESET and DISABLE signals, connect to the 24V
DC (XP24, XD24) terminal.
*2. Grounding resistance 100 Ω or less.
*3. This wiring is unnecessary when not using the PRESET function and the
DISABLE function.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
FX
2NC
-1HC
Special unit/block No. label
Manuals [Japanese version, English version]
1.2 External Dimensions, Part Names, and Terminal Layout
1
2
FX
2NC
-1HC
PW
UP
DN
φ A
φ B
DS
PR
YH
YS
3
20.2
15
(0.8")
(0.6")
Remark
Weight: Approx. 0.13kg (0.29lbs)
(Includes terminal block)
No.
Status LED
Power LED
PW
ON when the 5V power supply is normally supplied from the
(Green)
PLC.
UP (Red)
Up count LED
DN (Red)
Down count LED
φA
A phase input
φB
B phase input
DISABLE input
DS
LED
PRESET i nput
PR
LED
YH
YH output LED
YS
YS output LED
Terminal block (European type)
, FX
expansion bus. The
2NC
3UC
Extension connector (PLC side)
Used to connect this special function block to the FX
extension block.
Slide lock
Used to fix the FX
2NC
block.
Extension connector (Extension side)
Used to connect the FX
block. Remove this cover for connecting.
DIN rail mounting hook
-1HC unit to run only after
2NC
3.2.3
Differential-Line-Driver output encoders
When applying the Differential-Line-Driver encoder (AM26C31 or equivalent) to
FX
2NC
-1HC, connect the encoder output with the 5V DC terminal as shown in the left
*1
Encoder (NPN)
figure.
*1
+24V
FX
2NC
0V
FX
3UC
FX
-1HC
2NC
0.27k
A 5+
Phase
0.1k
A
A -
0.27k
B 5+
0.1k
B -
0.5k
Phase
XD 5
B
0.2k
COMD
0.5k
XP 5
0.2k
COMP
*3
DISABLE
*1. Grounding resistance 100 Ω or less.
*2. This wiring is unnecessary when not using the PRESET function and the
DISABLE function.
Phase
3.2.4
YH, YS output wiring [Sink wiring]
Z
*3
PRESET
FX
-1HC
2NC
YH+
YH-
-1HC,
2NC
YS+
YS-
3.2.5
YH, YS output wiring [Source wiring]
*1
Encoder (PNP)
FX
-1HC
2NC
+24V
YH+
*1
0V
YH-
YS+
Phase
A
YS-
4. Specifications
Phase
DESIGN
B
PRECAUTIONS
• Make sure to have the following safety circuits outside of the PLC to ensure safe
system operation even during external power supply problems or PLC failure.
Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection
circuit, an interlock circuit for opposite movements (such as normal vs.
*3
reverse rotation), and an interlock circuit (to prevent damage to the
equipment at the upper and lower positioning limits).
2) Note that when the PLC CPU detects an error, such as a watchdog timer
error, during self-diagnosis, all outputs are turned off. Also, when an error that
cannot be detected by the PLC CPU occurs in an input/output control block,
output control may be disabled.
*3
External circuits and mechanisms should be designed to ensure safe
Phase
machinery operation in such a case.
Z
3) Note that when an error occurs in a relay, triac or transistor output device, the
output could be held either on or off.
For output signals that may lead to serious accidents, external circuits and
mechanisms should be designed to ensure safe machinery operation in such
a case.
DESIGN
PRECAUTIONS
-1HC,
2NC
• Do not bundle the control line together with or lay it close to the main circuit or
power line. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit or power line.
Noise may cause malfunctions.
2. Installation, Connect to the PLC

INSTALLATION

PRECAUTIONS
Included Items
• Make sure to cut off all phases of the power supply externally before
1 Unit
attempting installation or wiring work.
1 Sheet
Failure to do so may cause electric shock or damage to the product.
1 manual each
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in PLC
Dimensions: mm (inches)
Terminal layout
main unit manual.
4
A24+
Never use the product in areas with excessive dust, oily smoke, conductive
A12+
A phase
dusts, corrosive gas (salt air, Cl
input
A5+
or impacts, or expose it to high temperature, condensation, or rain and wind.
5
A-
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
B24+
• When drilling screw holes or wiring, make sure cutting or wire debris does
B12+
B phase
not enter the ventilation slits.
input
B5+
Failure to do so may cause fire, equipment failures or malfunctions.
B-
• Connect FX
Loose connections may cause malfunctions.
XD24
• Use screwdrivers carefully when performing installation work, thus avoiding
DISABLE
XD5
accident or product damage.
input
COMD
2.1 Installation
6
XP24
PRESET
The FX
74(2.92")
XP5
input
COMP
2.2 Number of the connectable units
1) FX
YH+
YH
Up to four special function units/blocks in total can be connected to the
output
FX
YH-
2) FX
YS+
YS
Up to eight special function units/blocks in total can be connected to the
output
YS-
FX
FX
*1 Up to seven special function units/blocks in total can be connected to the
Name
FX
blocks begins with No.1.
2.3 Connection to the PLC
When connecting
the FX
the FX
Series main unit or
The respective LED is ON according to up/
extension block,
down count direction of the counter.
remove the
extension port
The respective LED is ON (flicker) according
cover from the right
to ON/OFF of φA and φB input.
side of the main
unit or extension
block, keep the
The respective LED is ON/OFF according to
slide lock in the
ON/OFF of PRESET and DISABLE input.
main unit or
extension block
pulled upward,
then align the hook
The respective LED is ON/OFF according to
in the FX
status of YH and YS output.
extension block.
Then push the slide lock downward to fix the FX
or more FX
unit in the same way.
, FX
main unit or
2NC
3UC
3. Wiring
WIRING
extension block on the right side of this special function
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
extension block to the right of this special function
2NC
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
4.1
The general specifications are equivalent to the PLC main unit.
(For general specifications, refer to the manual of the PLC main unit.)
4.2
Encoder
DC5V
*1
Class D
+5V
Units driving power
0V
Shielded
4.3 Performance Specifications
Twisted-Pair
LA
LAR
LB
LBR
*2
DISABLE
*2
PRESET
Shielded
Twisted-Pair
Input
signal
Output load driving
Fuse
power, 5 - 24V DC
Output load
driving power,
5 - 24V DC
Fuse
Count-
ing spec-
ification
Output
signal
I/O occupation
, H
S, SO
, or NO
), flammable gas, vibration
2
2
2
2
2NC
-1HC securely to their designated connectors.
2NC
-1HC can be installed on a DIN46277 rail (35 mm (1.38") wide).
2NC
PLC
2NC
Series PLC including those connected to the FX
2NC
-CNV-IF.
PLC
3UC
*1
Series PLC including those connected to the FX
-CNV-IF or
3UC
2NC
-1PS-5V.
3UC
3UC
-32MT-LT(-2) PLC. Unit numbers assigned to special function units/
-1HC to
2NC
/ FX
2NC
3UC
hook
FX
2NC
-1HC
Main unit
-1HC with the mounting hole in the former step of the main unit or
2NC
-1HC. When connecting two
2NC
-1HC units, connect an FX
-1HC unit to another FX
-1HC
2NC
2NC
2NC
General Specifications
Power Supply Specifications
Item
Specifications
5V DC, 90mA (Internal power supply from main unit or
extension power supply unit)
Specification
Item
[A24+],
24V DC±10%,
[B24+]
7mA or less
Phase A,
[A12+],
12V DC±10%,
Signal
Phase B
[B12+]
7mA or less
level
(Selected
[A5+],
3.0V to 5.5V DC,
by terminal
[B5+]
12.5mA or less
connec-
[XP24],
10.8V to 26.4V DC,
tion)
[XD24]
15mA or less
PRESET,
DISABLE
[XP5],
5V DC±10%,
[XD5]
8mA or less
1 input
1 - p h a s e
input
2 input
50kHz
MAX.
1 edge count
frequency
2 - p h a s e
2 edge count 25kHz
input
4 edge count 12.5kHz
t1
t1
t2
t2
t3
t3
Pulse
shape
t1(Rise/fall time):
3μs or less
t2(ON/OFF pulse):
6μs or more (at 50kHz)
t3(Phase difference between A and B):
3.5μs or more (at 50kHz)
PRESET(Z phase) input
100μs or more
DISABLE (count prohibit) input 100μs or more
Automatic UP/DOWN
However, when on 1-phase 1-input mode, UP/
DOWN is determined below.
• Hardware UP/DOWN:
Format
Up/down count is decided by OFF/ON of the A-
phase input terminal.
• Software UP/DOWN:
Up/down count is decided by the current value
(K0/K1) of BFM #1.
When 32-bit is specified:
-2,147,483,648 to +2,147,483,647
Range
When 16-bit is specified: 0 to 65,535
(upper limit is set up by BFM #3, #2.)
Each output is set when the present value of the
counter matches with the compare value, and is
switched OFF by a reset command.
Compari-
YH: Direct output processed by hardware.
son Type
YS: Software processed output with worst delay
time of 300μs.
Therefore, when the input frequency is 50 kHz,
there is a worst case delay of 15 input pulses.
YH +: transistor output for
YH+,
YH output
YS+
YH -: transistor output for
Types of
YH output
YH-,
outputs
YS +: transistor output for
YS-
YS output
YS -: transistor output for YS output
Output
5V ~ 24V DC, 0.5A
capacity
8 points (can be either inputs or outputs)