> 11482 ft.
> 3500 m
ft. (m)
> 9842 - 11482 ft.
(> 3000 - 3500 m)
> 8202 - 9842 ft.
(> 2500 - 3000 m)
> 6561 - 8202 ft.
(> 2000 - 2500 m)
0 - 6561 ft.
(0 - 2000 m)
6
Altitude above sea level: up to 11,482 ft. (3500 m)
max.
IMPORTANT! The inverter must not be installed or operated above an
11482 ft.
3500 m
altitude of 11,482 ft. (3500 m).
The max. permissible DC voltage of the inverter depends on the altitude:
-
0
-
> 6561 - 8202 ft. (> 2000–2500 m) ... U
-
> 8202 - 9842 ft. (> 2500–3000 m) ... U
-
> 9842–11482 ft. (> 3000–3500 m) ... U
U
DC max
430 V
The output power reduces when the device temperature is too high, and
480 V
this may occur earlier than normal at increased altitudes.
540 V
550 V
Do not install the inverter:
NH
3
-
where it may be exposed to ammonia, corrosive gases, acids or
salts
(e.g., fertilizer storage areas, vent openings for livestock stables,
chemical plants, tanneries, etc.)
During certain operation phases the inverter may produce a slight noise.
For this reason it should not be installed in an occupied living area.
Do not install the inverter in:
-
areas where there is an increased risk of accidents, e.g., from farm
animals (horses, cattle, sheep, pigs, etc.)
-
stables or adjoining areas
-
storage areas for hay, straw, chaff, animal feed, fertilizers, etc.
Do not install the inverter in:
-
dusty rooms and environments
-
rooms and areas with large amounts of conducting dust particles
(e.g., iron filings)
Do not install the inverter in:
-
greenhouses
-
storage or processing areas for fruit, vegetables, or viniculture prod-
ucts
-
areas used in the preparation of grain, green fodder, or animal feeds
- 6561 ft. (0
- 2000 m) ... U
= 550 V
DC max
= 540 V
DC max
= 480 V
DC max
= 430 V
DC max