Prp Statistic - Siemens SCALANCE X-200RNA Operating Instructions Manual

Industrial ethernet switches for simatic net
Hide thumbs Also See for SCALANCE X-200RNA:
Table of Contents

Advertisement

Functional description and configuration using Web Based Management
7.10 The "Switch" menu
7.10.9

PRP Statistic

PRP Statistic
The "PRP Statistic" dialog box shows interesting statistical data for the PRP protocol. The
following events are distinguished:
● "Received A Frames at PRP A Port"
Number of valid A frames received at port PRP A.
● "Received B Frames at PRP B Port"
Number of valid B frames received at port PRP B.
● "Received B Frames at PRP A Port"
Number of B frames received at port PRP A (error).
● "Received A Frames at PRP B Port"
Number of A frames received at port PRP B (error).
If you click the "Reset Counters" button, you reset this counter for all ports.
Figure 7-46
PRP Statistic
134
Operating Instructions, 10/2016, C79000-G8976-C342-04
SCALANCE X-200RNA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance x204rna eec

Table of Contents