Management Software - Sun Microsystems QLogic SANbox 5600 Manual

Stackable fc switch hardware
Table of Contents

Advertisement

Installing the Switch Into an Existing Fabric
If you are installing a QLogic SANbox 5600 and 5602 FC switch into an existing
fabric that has a QLogic switch or a Sun StorEdge™ Network FC switch, you must
do the following:
1. Remove all 1-Gbit QLogic and Sun StorEdge Network 1-Gbit FC switches from
the fabric.
2. Upgrade any QLogic or Sun StorEdge Network 2-Gbit FC switches to the
minimum firmware version 5.0.1.10. The patch ID for this firmware is 119553. See
the section
information regarding the installation of patches.

Management Software

You can manage the QLogic SANbox 5600 and 5602 FC switches using Enterprise
Fabric Suite (EFS), QuickTools, or the CLI.
software and firmware version compatibility requirements for the SANbox 5600 and
5602 FC switches.
TABLE 1
Firmware Version
5.0.1.10
6.7.0.07
EFS Requirements
If using EFS, firmware version 6.7.0.07 is required. For further SANbox 5600 and
5602 FC switch firmware information, see the section
page
downloading procedure.
▼ Downloading EFS
1. Access the following QLogic web site:
http://lk.qlogic.com/productfeatureautomation/Home.aspx?id=
m13
2. Under the Download section, click Enterprise Fabric Suite 2007 - Download
Center.
4
QLogic SANbox 5600/5602 Stackable FC Switch Hardware Release Notes • January 2008
"Downloading and Installing Patches" on page 5
Management Software and Firmware Version Compatibility
Firmware Patch ID
119553-03
128175-01
3. See the section
"Downloading EFS" on page 4
summarizes the management
TABLE 1
Management Software Version
SANSurfer Switch Manager 5.00.05
EFS 6.07.05 (minimum)
"Firmware Requirements" on
for the EFS software
for further

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QLogic SANbox 5600 and is the answer not in the manual?

This manual is also suitable for:

Qlogic sanbox 5602

Table of Contents