Main code 92 : Synchronizing system error
(The "system control" described below means IC2008 on the DPR-224 board.)
Main code
Sub code
92
101
102
103
104
105
10A
Main code 95 : Communication error with digital process system ICs
(The "system control" described below means IC2008 on the DPR-224 board.)
Main code
Sub code
95
100
101
102
103
111
112
113
114
115
116
117
118
119
11A
11B
11C
11D
11E
121
122
123
124
125
126
127
128
129
12A
3-4 (E)
Description
System control detected abnormality in REF FOE.
System control detected abnormality in P-TRKT.
System control detected abnormality in P-FLTT.
System control detected abnormality in R-TRKT.
System control detected abnormality in R-FLTT.
System control detected abnormality in REC FOE.
Description
Communication error between system control and bridge (IC2601/DPR-224 board) is detected.
Communication error between system control and south bridge (IC2201/DPR-224 board) is detected.
Communication error between system control and i.LINK (IC2401/DPR-224 board) is detected.
Communication error between system control and Ether (IC601/DIF-140 board) is detected.
Communication error between system control and C1-R mode (IC1307/DPR-224 board) is detected.
Communication error between system control and F1-R (IC1402/DPR-224 board) is detected.
Communication error between system control and V2-R (IC1402/DPR-224 board) is detected.
Communication error between system control and VAI-R (IC2901/DPR-224 board) is detected.
Communication error between system control and Video Dec (IC100/DDE-18 board) is detected.
Communication error between system control and DIF-R (IC801/DPR-224 board) is detected.
Communication error between system control and AIFQ (IC1905/DPR-224 board) is detected.
Communication error between system control and MPEG ENC (IC1801/DPR-224 board) is detected.
Communication error between system control and ENC1 DSP (IC1101/DPR-224 board) is detected.
Communication error between system control and ENC2 DSP (IC1102/DPR-224 board) is detected.
Frame communication error between system control and A1-R Front (IC2701/DPR-224 board) is detected.
Track Pair communication error between system control and A1-R Front (IC2701/DPR-224 board) is
detected.
Frame communication error between system control and A1-R Rear (IC2701/DPR-224 board) is detected.
Track Pair communication error between system control and A1-R Rear (IC2701/DPR-224 board) is
detected.
Communication error between system control and C1-P mode (IC1309/DPR-224 board) is detected.
Communication error between system control and F1-P (IC1413/DPR-224 board) is detected.
Communication error between system control and V2-P (IC1413/DPR-224 board) is detected.
Communication error between system control and VAI-P (IC2901/DPR-224 board) is detected.
Communication error between system control and Video Enc1 (IC100/DEN-20 board) is detected.
Communication error between system control and Video Enc2 (IC101/DEN-20 board) is detected.
Communication error between system control and NSG (IC2901/DPR-224 board) is detected.
Communication error between system control and AIF-P (IC1505/DPR-224 board) is detected.
Communication error between system control and MPEG DEC (IC1701/DPR-224 board) is detected.
Communication error between system control and DEC DSP (IC1202/DPR-224 board) is detected.