CAUTIONS 
 
CAUTIONS identify conditions and actions that could cause DAMAGE to the meter or equipment 
under test. Do not expose the meter to extremes in temperature or high humidity. 
Safety Symbols that are typically marked on meters and instructions 
 
 
 
 
 
 
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 
OVERVOLTAGE CATEGORY I 
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which 
measures are taken to limit the transient over‐voltages to an appropriate low level. 
Note – Examples include protected electronic circuits. 
OVERVOLTAGE CATEGORY II 
Equipment of OVERVOLTAGE CATEGORY II is energy‐consuming equipment to be supplied from 
the fixed installation. 
Note – Examples include household, office, and laboratory appliances. 
OVERVOLTAGE CATEGORY III 
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 
Note – Examples include switches in the fixed installation and some equipment for industrial use 
with permanent connection to the fixed installation. 
OVERVOLTAGE CATEGORY IV 
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 
Note – Examples include electricity meters and primary over‐current protection equipment 
800.561.8187
This symbol, adjacent to another symbol, indicates the user must refer to the 
manual for further information. 
Do not apply or remove clamp from HAZARDOUS LIVE conductors 
Equipment protected by double or reinforced insulation 
Battery symbol 
 
Conforms to EU directives 
 
Do not discard this product in household trash. 
AC measurement 
 
Earth ground 