pictor M1606
Commissioning
7.3.5 Connecting the trigger cable
Perform the following steps only in de-energiesed state:
1. Insert the 6-pin HIROSE plug of the trigger cable into the Trig. socket on the
device.
2. Connect the open end of the trigger cable to control unit.
Video
Pin assignment trigger cable
Pin
Colour
1
green
2
brown
3
white
4
violet
5
grey
6
yellow
Table 14: Pin assignment trigger cable
© Vision & Control GmbH 2014
LAN
I/O
Trig.
Assignment
RS232 TxD Out
+5 V DC Out
GND
RS232 RxD
Trigger Out
+5 V TTL
1
2
3
Open cable end
Send data
Power +5 V
Ground
Receive data
Output trigger
Input trigger
999.994.256.10-en-1.4
6
5
4
40