7.3.4 Connecting the RS232 cable

Perform the following steps only in de-energiesed state:
1. Insert the 6-pin HIROSE plug of the RS232 cable into the Trig. socket on the
device.
2. Plug the D-Sub plug into a free serial port (COM) of the process control
system or the key pad, and screw tight.
Video
Pin assignment RS232 cable
Pin
Signal
1
TxD
2
+ 5 VDC Out
3
GND
4
RxD
5
Trigger Out
6
+5 V TTL
* Only for key pad.
Table 13: Pin assignment RS232 cable
39
999.994.256.10-en-1.4
LAN
I/O
Trig.
Description
Send data
Power + 5 V DC*
Ground
Receive data
Trigger output*
Trigger input*
Commissioning
1
6
2
5
3
4
D-Sub pin
2
*
5
3
*
*
© Vision & Control GmbH 2014