Ethernet Interface - Vision & Control Pictor M1606 Instructions For Use Manual

Intelligent camera
Table of Contents

Advertisement

pictor M1606
Product Data
Parameter Digital Outputs
Parameter
Number of outputs
Power supply*
Switched potential
Output current per output
Output current all outputs
Switching power 24 V DC, 500 mA
Protection against short circuit
* external via Pin 1 and Pin 9 Digital IN

5.1.2 Ethernet interface

The device has an Ethernet interface for communicating with a host computer
or network.
• Manage up to 16 simultaneous TCP / IP connections
• Server port 8500 (initialization with vcwin pro)
• Data rate: 100 Mbit
IP configuration in the as-supplied state
The device first attempts to have an IP address assigned from a DHCP. If an IP
address is not assigned by a DHCP server, the device has to be configured as
follows:
• Static configuration
• IP address 192.168.0.65
• Subnet mask 255.255.255.0
• Gateway 192.168.0.254
© Vision & Control GmbH 2014
Min
Nom
9.8 V
24 V
power supply
present
999.994.256.10-en-1.4
Max
4
28 V
500 mA
1 A
12 W *
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

4-20-1934-20-194Pictor m41/el

Table of Contents