Commissioning

7.2 Mounting

Cable damaged by a bending radius that is too small and the lack of a
strain relief clamp.
• Comply with the specified minimum bending radius.
• Cables must generally be mounted with a strain relief clamp.
• Use cables corresponding to the specification (see data sheet).
Mounting of cables
When mounting the cable to the device, hold the device and plug the cable into
the connector.
Mounting the device
To install the device, a mounting block with two tapped holes M6 and a 1-32
UN 2A thread is located at the bottom.
Distance between the tapped holes
Maximum screwed-in depth
Maximum tightening torque
Table 9: Properties of the tapped holes
© Vision & Control GmbH 2014
DAMAGE OF PROPERTY
25 mm
7 mm
10 Nm