4-4. Remote Receptacle (RCTY)

1

4-5. Welding Process Selection

L1
L2
L3
L4
P3
L1 LED
L2 LED
L3 LED
L4 LED
P3 Push Button
Press P3 until desired process LED illumi-
nates.
Values and parameters that appear on D1
and D2 are either factory default settings or
last settings entered for the selected pro-
cess.
L1 selection is Manual MIG welding.
D1 value is welding voltage, default is
18.5V (range is 10 V to 50 V).
D2 value is wire feed speed, default is 5.0
m/min (range is 1 m/min to 20 m/min). See
Section 4-11.
L2 Synergic MIG welding (non-pulsed).
D1 value is welding voltage, default is 16.5
V (range is −10 V to 50 V).
D2 value is the unit of measure as determ-
ined in the setup menu. (IPM, MPM, Cur-
rent and Thickness)
.
When L2 LED is stable the welding arc
is in a Short Circuit or Spray Arc trans-
fer. If L2 is flashing this indicates that
the welding parameters are outside of
the specific setting required for either
arc transfer to exist. This process is
known as Globular Arc transfer. This
process produces considerable un-
desirable welding spatter. It may be de-
sirable to switch to a Pulsed-MIG Arc
transfer to reduce/eliminate welding
spatter.
L3 Synergic Pulsed MIG welding.
1
7 Pin Remote Receptacle
Ref. 956142645-5-5
D1 value is welding voltage, default is 20
V (range is −10 V to 50 V).
D2 value is the unit of measure as determ-
ined in the setup menu. (IPM, MPM, Cur-
rent and Thickness)
L4 Lift-TIG process (see Section 4-16) or
Stick process (see Section 4-17).
If selected process is TIG:
D1 displays TIG, and D2 value is welding
current, default is 220 A (range is 10 A to
400 A).
If selected process is Stick:
D1 displays Stick welding. Output is not en-
abled until button P7 is set to Output en-
abled mode. Display D1 displays open cir-
cuit voltage (OCV) at approximately 85
VDC. Display D2 displays welding current,
default is 220 A (range is 10 A to 400 A).