Selecting Synergic Mig Welding - Miller XMS 403 Owner's Manual

400 volts ce arc welding power source
Table of Contents

Advertisement

4-13. Selecting Synergic MIG Welding

Set Synergic MIG welding process using
P3 push button.
In Synergic MIG mode, the operator may
need to adjust welding data (wire type, wire
diameter, and gas type) and only one weld
parameter. Generally, wire feed speed is
adjusted and the synergic process auto-
matically sets appropriate weld voltage.
Synergic welding also sets many secon-
dary welding parameters automatically for
improved weld quality.
D1 value is default voltage setting (range is
OM-244 243 Page 24
E1
D1
P3
P4
P5
defined by wire type, wire diameter and gas
type selection).
D2 value is the default current setting
(range is defined by wire type, wire diame-
ter and gas type selection).
During Synergic MIG Welding:
D1 value is Measured Welding Voltage in
Volts.
D2 value is Measured Welding Amperage
in Amperes.
See Wire Feeder manual for all remaining
Synergic MIG settings.
D2
E2
P6
P7
Select wire type using P4 push button.
Select wire diameter using P5 push button.
Select gas using P6 push button.
Select trigger mode using P7 push button.
See Wire Feeder manual for remaining
Synergic MIG settings.
Setting Cooler Status (see Section 4-3 )
.
To prevent damage to water-cooled
torch and components, be sure that
coolant is turned on.
Ref. 956142645-5-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents