Hold down the PROG button (part. 15, fig. A) for about 3 seconds until led LD1
lights up (part. 18, fig. A)
LD1
The ECU is now in the programming stage.
Press button P/P (part. 17, fig. A) the gate with motor M2 should begin to close, if it
moves in the opening direction instead, stop programming by switching off the
power, invert the wires (21-22) of motor M2 and repeat the procedure from point
(1).
M2
When the gate leaf with M2 has completely closed it will stop and the other motor
(M1) will begin to close.
If the motor rotates in the wrong direction, switch off the power, invert the wires of
M1 and repeat the programming procedure from point (1).
M2
If the motors stop before reaching the travel limits, increase the power
trimmer.
M2
When the gate leaf with M1 has completely closed it will stop and start to open
automatically.
M2
Press P/P again when M1 has reached the desired gate delay angle, the motor will
stop for a second and then start to open again.
After this point we can manually insert the DECELERATION start points
using P/P (DIP 9 set to ON) the motor will stop for a second then start again.
Otherwise wait until the gate reaches the travel limit.
M2
When the gate with M1 has opened completely, the motor will stop and the other
M2
motor (M2) will start to move automatically.
After this point we can manually insert the DECELERATION start points
using P/P (DIP 9 set to ON) the motor will stop for a second then start again.
Otherwise wait until the gate reaches the travel limit.
M2
When the gate with M2 has opened completely (reached the travel limit), the motor
will stop and the pause time memorisation will start (if automatic reclosing is not
being used you may move directly to point (11).
M2
Once the desired pause time has elapsed, press button P/P and motor M2 will
begin to close.
M2
Press P/P again when M2 has reached the desired gate delay angle, the motor will
stop for a second and then begin to close again.
At this point you can manually insert the DECELERATION start point using
P/P if DIP 9 is set to ON. The motor will stop for a second and then begin to
move again. Otherwise wait until the gate reaches the travel limit.