Radio Thermostat CT102 User Manual page 20

Communicating touch screen thermostat
Table of Contents

Advertisement

6 Wire Heat/Cool
1. Connect the W wire to the W
terminal. This connects the heat.
2. Connect the Y wire to the Y
terminal. This connects to the
cooling compressor.
3. Disconnect the Rc and Rh
terminals by placing the
removing the Jumper Wire.
4. Connect the RH wire to the RH terminal and the RC wire to the RC
terminal. This connects power.
5. Connect the G wire to the G terminal. This connects the fan.
6. Connect the C wire to the C terminal. Your HVAC system is now
connected to the CT102.
7. Go to "Connect Your Wires" on
Multi-stage Heat & Multi-Stage Cool
The CT102 can handle up to 2
stages of HEAT and 2 stages of
COOL.
1. Connect the W and W2 wires to
the W and W2 terminals. This
connects the stages of HEAT.
2. Connect the Y and Y2 wires to
the Y and Y2 terminals. This
connects the stages of COOL.
3. Connect the RH or R wire to the RH terminal. This connects the
power.
4. Connect the G wire to the G terminal. This connects the fan.
5. Connect the C wire to the C terminal. Your HVAC system is now
connected to the CT102.
6. Go to "Connect Your Wires" on
20
Installation Guide CT102
Wiring Diagrams
POWER
C B O W
W
THERMOSTAT TERMINALS
page
X.
HVAC SYSTEM
C
POWER
C B O W
W
THERMOSTAT TERMINALS
page
X.
HVAC SYSTEM
C
W
Y R
R
H
C
Y Y
R
RC G A
2
2
H
*R
and R
disconnected
C
H
W
Y Y
R
W
2
2
Y Y
R
RC G A
2
2
H
G
G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct102r1

Table of Contents