Number of
Flashes
1
2
Low Battery Fault
3
High Battery Fault
4
Current Limit Time-out
5
6
Throttle OONAPU
7
8
Motor Voltage Fault
9
www.careco.co.uk
09
Description
Battery Low
Park Brake Fault
Speed Pot Fault
Other error
The batteries are running low.
Recharge the batteries.
The batteries have run out of charge.
Recharge the batteries.
Battery voltage is too high. This may occur if overcharged &/or
travelling down a long slope.
• If travelling down a slope, reduce your speed to minimize the
amount of regenerative charging.
• Check the battery and associated connections and wiring.
The motor has been exceeding its maximum current rating for
too long. This may be due to a faulty motor.
• Check the motor and associated connections and wiring.
• Turn the controller off, leave for a few minutes and turn back
on again.
Either a park brake release switch is active or the park
brake is faulty.
• Check the park brake and associated connections and wiring.
• Ensure any associated switches are in their correct positions.
The Throttle is out of neutral when turning the controller on.
• Ensure the throttle is in neutral when turning the controller on.
• The Throttle may require re-calibration.
The throttle, speed limit pot or their associated wiring may
be faulty. Check the throttle and speed pot and associated
connections and wiring.
The motor or its associated wiring is faulty.
Check the motor and associated connections and wiring.
The controller may have an internal fault.
Check all connections & wiring.