Sharp MX-C250 Service Manual page 136

Digital full color multifunctional system
Hide thumbs Also See for MX-C250:
Table of Contents

Advertisement

'13/Oct
2
The scanner (CIS) color balance automatic adjustment is per-
formed.
63-5
Adjustment/Setup
Purpose
Function (Purpose) Used to perform the scanner (CIS) color
balance and gamma default setting.
Section
Operation/Procedure
1) Press [OK]/[START] key.
2) The scanner (CIS) color balance and gamma are set to the
default.
63-12
Adjustment/Setup
Purpose
Function (Purpose) Change the lighting time for each lamp by
2
setting the RGB mixing ratio (value), And,
LED lights in the ratio set in this mode with
monochrome mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
Item/Dis-
Contents
play
R-Ratio
Red mixing ratio (R)
G-Ratio
Green mixing ratio (G)
B-Ratio
Blue mixing ratio (B)
Default
Range
value
0-100
20
0-100
70
0-100
10
MX-C250 SIMULATION 6 – 59