Sharp MX-C250 Service Manual page 101

Digital full color multifunctional system
Hide thumbs Also See for MX-C250:
Table of Contents

Advertisement

43
43-1
Setting
Purpose
Function (Purpose) Used to set the fusing reference tempera-
ture of each operation mode.
Section
Item/Display
1
HL_UM READY
2
HL_UM PLAIN PAPER BW
3
HL_UM PLAIN PAPER CL
4
WARM UP END TIME
5
HL_UM PRE-JOB
6
HL_UM WARMUP_120L
7
HL_UM WARMUP_120H
8
HI_WU_FM_ON_TMP
9
HI_WU_END_TIME
10
HI_WU_JOB_SET_TMP
11
LO_WU_JOB_SET_TMP
12
HL_UM_JOB_SET_TMP_BW
1
HL_UM READY
2
HL_UM PLAIN PAPER BW
3
HL_UM PLAIN PAPER CL
4
WARM UP END TIME
5
HL_UM PRE-JOB
6
HL_UM WARMUP_120L
7
HL_UM WARMUP_120H
8
HI_WU_FM_ON_TMP
9
HI_WU_END_TIME
10
HI_WU_JOB_SET_TMP
11
LO_WU_JOB_SET_TMP
12
HL_UM_JOB_SET_TMP_BW
1
WARMUP FUMON TMP
2
WARMUP FUMOFF
3
HL_UM HEAVY PAPER
4
HL_UM OHP PAPER
5
HL_UM ENV PAPER
6
HL_UM GLOSS PAPER
7
HL_UM E-STAR
8
HL_UM HEAVY2 PAPER
9
LO_WARMUP_TIME
10
HI_WARMUP_TIME
11
HI_WARMUP_BORDER
12
JOBEND_FUMON_TIME
<Code descriptions>
TH_UM
Fusing upper thermister (main)
TH_LM
Fusing lower thermister (main)
TH_E
Fusing thermister (external heat roller)
Group
Group A
Japan
Group B
U.S.A.
Ready standby TH_UM set value
Black-White plain paper TH_UM set value
Color plain paper TH_UM set value
Warm-up complete time
Resetting from preheating TH_UM set value
Warm-up TH_UM set value (when the fusing temperature is under 120dgrees C)
Warm-up TH_UM set value (when the fusing temperature is 120degrees C or
above)
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha
C or above)
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha C
or above)
Job Ready TH_UM temperature (when the fusing temperature in warm-up is alpha
C or above)
Job Ready TH_UM temperature (CL) (When the fusing temperature in warming up
is under alpha degree C.)
Job Ready TH_UM temperature (BW) (When the fusing temperature in warming up
is under alpha degree C.)
Ready standby TH_UM set value
Black-White plain paper TH_UM set value
Color plain paper TH_UM set value
Warm-up complete time
Resetting from preheating TH_UM set value
Warm-up TH_UM set value (when the fusing temperature is under 120dgrees C)
Warm-up TH_UM set value (when the fusing temperature is 120degrees C or
above)
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha
C or above)
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha C
or above)
Job Ready TH_UM temperature (when the fusing temperature in warm-up is alpha
C or above)
Job Ready TH_UM temperature (CL) (when the fusing temperature in warm-up is
under alpha C)
Job Ready TH_UM temperature (BW) (when the fusing temperature in warm-up is
under alpha C)
Fusing motor pre-rotation start TH_US set value (under alpha degrees)
Preheating TH_E set value
Resetting from preheating TH_UM set value (Job Ready temperature)
Preheating TH_LM set value
Warm-up TH_UM set value (when the fusing temperature is 120 C or less)
Warm-up TH_LM set value (when the fusing temperature is 120 C or less)
Warm-up TH_E set value (when the fusing temperature is 120 C or less)
Heavy paper 2 TH_UM set value
The applying time in WUP TH_UM of 120dgrees C or less (Timer from completion of
warm-up)
The applying time in WUP TH_UM of 120dgrees C or above (Timer from completion
of warm-up)
The threshold value alpha degree C or above in warm-up.
Fusing motor after rotation time after completion of a job (Excluding heavy paper,
OPH, and envelopes)
HL_UM
HL_LM
HL_E
Destination
China
Canada
MX-C250 SIMULATION 6 – 24
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
NOTE:
The set value is the reference value, and it may differ from
the actual fusing temperature depending on the operating
conditions.
Content
Heater lamp upper
Heater lamp lower
Heater lamp (external heat roller)
AB_B
-
Inch
-
Setting
Group
Group
Group
range
A
B
70 - 230
150
160
160
70 - 230
160
170
170
70 - 230
165
175
175
30 - 255
13
13
13
30 - 200
155
165
165
70 - 230
155
165
165
70 - 230
165
175
175
30 - 200
105
105
105
0 - 255
13
13
13
70 - 230
155
165
165
70 - 230
155
165
165
70 - 230
150
160
160
70 - 230
160
165
165
70 - 230
170
175
175
70 - 230
175
180
180
30 - 255
13
13
13
30 - 200
165
170
170
70 - 230
175
180
180
70 - 230
175
180
180
30 - 200
105
105
105
0 - 255
13
13
13
70 - 230
165
170
170
70 - 230
165
170
170
70 - 230
160
165
165
70 - 230
150
160
160
70 - 230
160
170
170
70 - 230
165
175
175
30 - 255
13
13
13
30 - 200
155
165
165
70 - 230
155
165
165
70 - 230
165
175
175
30 - 200
105
105
105
0 - 255
13
13
13
70 - 230
155
165
165
70 - 230
155
165
165
70 - 230
150
160