Download Print this page
F&F PCZ-522.3 Manual

F&F PCZ-522.3 Manual

Programmable control timer dual-channel

Advertisement

Quick Links

F&F Filipowski sp. j.
Konstantynowska 79/81
95-200 Pabianice
tel/fax +48 42 2152383; 2270971
http:/www.fif.com.pl
e-mail: fif@fif.com.pl
PROGRAMMABLE CONTROL TIMER
PCZ-522.3
dual-channel
5
9 0 8 3 1 2
5 9 3 2 5 6
PURPOSE
Programmable control timer is used to time control the devices in home or
industrial automation systems according to an individual time program set by
the user.
OPERATION
Timer activates and deactivates the device or electrical circuit on the
programmed hours in cycles: daily, weekly, working days (Mon-Fri)
or weekend (Sat, Sun). The timer has two independently programmable
channels.
OPERATING MODES AND FUNCTIONS
CHANNEL – program line with individual entries for ON-OFF COMMANDS,
which controls its own contact for enabling the receiver.
ON-OFF COMMAND – program entry for enabling or disabling the receiver.
500 MEMORY CELLS – memory for individual program entries that allows to
program 250 pairs of ON-OFF COMMANDS.
AUTOMATIC MODE - operation by ON-OFF COMMANDS programmed by the
user in the timer memory [highlighted
icon on display]
MANUAL MODE - [ON] permanently closed contact (position 1-5) or [OFF]
permanently open contact (position 1-6) when the AUTOMATIC MODE is off
[no
icon on display]
CYCLE - adjustable, weekly cycle (7 days from Monday to Sunday) of the
receiver switching in accordance with the programmed ON-OFF COMMANDS:
* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday).
AUTOMATIC TIME CHANGE - change from winter time to summer time with
options to change automatically or not. User can set the time zone so that the
switching time is consistent with the local time
DATE PREVIEW - the ability to preview the set date (OK.)
CURRENT PROGRAM PREVIEW – pressing the +/- keys in the date preview
mode displays information about the number and details of the current
program.
NFC WIRELESS COMMUNICATION - wirelessly read and write timer
configuration from an Android phone equipped with the NFC module.
PCZ Konfigurator APP - free application for Android mobile phones and
tablets equipped with the NFC module for wireless communication.
Features: · timer configuration in Offline mode (without the connection with
the PCZ-521 timer);
· read and write the configuration of the controller;
· quick programming of multiple controllers using a single configuration;
· read and write the configuration from and to a file;
· sharing the configuration via e-mail, Bluetooth, network drives...
· identification of the connected timer and the ability to name individual
devices;
· automatic backups of the configuration. Along with a unique identifier for
each timer, user can easily restore previous configuration;
· set the time and date according to the clock in mobile phone;
The app is available on Google Play!
CLOCK TIME CORRECTION – set monthly adjustment of the seconds of the
system clock.
BATTERY INDICATOR - the controller comes with built-in control system of the
backup timer battery used in case of main power supply failure. If the battery
is low, user will receive information that the battery needs to be replaced.
Battery life depends on the ambient temperature and the degree of the
battery wear.
-1-
LCD BRIGHTNESS ADJUSTMENT - change the contrast of the display to get
aclear LCD read-out from different viewing angles.
POLAND
RELAY STATE MEMORY - the relay state in manual mode will be remembered
even after power supply failure.
DISPLAY AND CONTROL PANEL DESCRIPTION
Mo T
W
T
F
R
S
A
S
U
E
H
DATE AND TIME /
/ PROGRAM ENTRIES
ş
ş
1
ON
2
OFF
MODE INDICATOR /
/ AUTOMATIC MODE
OK
MENU
+
Mo – Monday; Tu – Tuesday; We – Wednesday; Th – Thursday; Fr – Friday;
Sa – Saturday; Su – Sunday.
FUNCTION KEYS DESCRIPTION
MENU:
- enter the program menu
- return to the previous position (back).
OK:
- move to the next setting
- accept setting
- preview of the date
+ [Plus]:
- change the setting by one position up for the selected programming option
(holding down the button continuously changes the setting by one position
up in a loop)
- in MANUAL MODE: permanent ON and OFF contact switching
- [Minus]:
- change in the setting by one position down for the selected programming
option (holding down the button continuously changes the setting by one
position down in a loop)
- in MANUAL MODE: permanent ON and OFF contact switching
PROGRAMMING
1. START
1.1 Connect the power supply.
1.2 The timer will start at the root level and the display will show selected
hour.
Mo
T
U
W
E
T
H
F
R
S
A
S
U
1
OFF
In the absence of any program entries, timer will automatically run in manual
mode. If the previous entries are present, timer will execute the program.
To erase all previous settings, see section 5.6.
1.3 Set individual timer program with internal configuration menu or by using
the "PCZ Konfigurator" app for mobile devices.
2. DATE
Press MENU. The timer will enter program menu. Using the +/- buttons
select the date setting mode [date]
Confirm with OK.
-2-
Timer will show settings for the next parameters: year, month, and day. Use
the +/- keys to set the parameters; move to the next parameter with the OK
button. Go back to the previous item by pressing MENU.
Press OK to accept date setting. The timer will automatically exit from the
DAYS OF THE WEEK /
U
/ CYCLE
date setting mode and go to the program menu.
CHANNEL NUMBER
The date setting is tantamount to time determination: winter or summer.
In Poland, the time change from winter to summer is done automatically at
ON
OFF
night, on the last Sunday of March at 2.00 AM (by adding one hour to the
current time). Time change from summer to winter is done automatically at
INDICATION OF CONTACT
night, on the last Sunday of October at 3.00 AM (by subtracting one hour
POSITION
from the current time).
PLEASE NOTE!
The automatic time change can be turned off (see section 5.1).
3. TIME
Press MENU. The timer will enter the program menu. Using the +/- buttons
select the mode for time setting [hour]
Timer will show settings for the next parameters: hour and minutes. Set the
parameters with the +/- buttons. Move to the next parameter with the OK
button. Go back to the previous item by pressing MENU.
Press OK to accept time entry. The timer will automatically exit from the date
setting mode and go to the program menu.
4. CHANNEL – Selecting a channel number and setting its parameters
Press MENU. The clock will enter the program menu. Using +/- buttons select
the mode for the date setting: "Chn 1" or "Chn 2".
Select channel 1 or 2, and accept with OK button.
Timer will show the submenu of the selected channel parameter settings:
on-off commands, edit, delete and mode select.
Select the desired entry with the +/- buttons. Open the desired item with OK
button.OK. Press MENU button to return to the main MENU.
4.1 ON-OFF COMMAND - setting the parameters
Using the +/- buttons select the mode for the date setting [prog].
Press OK to accept. The clock will enter the memory cell number selecting
mode. The display will automatically show the number of the first empty
memory cell.
Press OK to accept (or select another number using the +/- keys). Clock will
enter the single ON-OFF COMMAND parameters setting mode.
A. Operation cycle
Set OPERATION CYCLE using the +/- keys:
* single day of the week: Mo; Tu; We; Th; Fr; Sa or Su.
* working days: Mo Tu We Th Fr (Monday to Friday).
* weekend: Sa Su (Saturday and Sunday)
* daily: Mo Tu We Th Fr Sa Su (Monday to Sunday)
Press OK to accept.
B. Hour and minutes
Timer will show setting for the next parameters: hour and minutes. Set the
values using +/- keys; move to the next parameter with the OK button. Go
back to the previous item by pressing MENU.
Mo T
U
ş
1
ON
OFF
C. ON / OFF
Timer will allow to choose [ON] or [OFF] option.
Set ON or OFF using +/- keys; confirm with OK. Timer will automatically enter
the next ON-OFF COMMAND parameter input mode. Go back to the previous
item by pressing MENU.
PLEASE NOTE!
* The registered ON-OFF commands do not constitute solid pairs of
commands for a contact opening and closing. They are treated as individual
commands and executed in accordance with the specified time chronology.
Cases of overlapping contact closing times from two pairs of ON-OFF
commands are illustrated in the following diagrams:
entry 1
entry 2
contacts 1-5
entry 1
entry 2
contacts 1-5
* Time of contact closing established by a pair of ON-OFF commands can be
longer than 24 hours, which means that [ON] command can be set to any
time and any day of the week (e.g. Tuesday, 1:45 PM) and [OFF] command to
any hour of any other day of the week (e.g. Thursday, 5.05 PM).
4.2 EDITION OF ON / OFF COMMANDS PARAMETERS
Using the +/- keys select the parameter edit mode "edit"
1
Press OK to accept. The timer will enter the memory cell number selecting
mode. Select the cell to edit and accept by pressing OK.
Mo
T
W
T
F
S
S
U
E
H
R
A
U
Proceed as with ON-OFF COMMAND parameters setting (see section 5.1).
ş
1
ON
OFF
-3-
Mo T
W
T
F
S
S
Mo T
W
T
F
S
S
W
E
T
H
F
R
S
A
S
U
U
E
H
R
A
U
U
E
H
R
A
U
ş
ş
1
ON
1
ON
OFF
OFF
Mo T
W
T
F
S
S
U
E
H
R
A
U
ş
1
ON
OFF
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 2
OFF 2
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 1
OFF 1
ON 2
ON 2
entry 1
entry 2
contacts 1-5
ON 1
OFF 1
ON 1
OFF 1
OFF 2
OFF 2
Mo T
W
T
F
S
S
U
E
H
R
A
U
ş
1
ON
1
OFF
Continued on page 5
-4-

Advertisement

loading

Summary of Contents for F&F PCZ-522.3

  • Page 1 * weekend: Sa Su (Saturday and Sunday) even after power supply failure. PROGRAMMABLE CONTROL TIMER * daily: Mo Tu We Th Fr Sa Su (Monday to Sunday) PCZ-522.3 dual-channel Press OK to accept. DISPLAY AND CONTROL PANEL DESCRIPTION B. Hour and minutes Timer will show setting for the next parameters: hour and minutes.
  • Page 2 Continued from page 4 BATTERY REPLACEMENT 5.2 Time zone – utc 4.3 DELETION – removing entries User can single-handedly replace the battery. Detailed instructions with Using the +/- keys select ON-OFF COMMANDS reset mode "del". pictures and videos can be found on the website www.fif.com.pl on the subpage of the timer.
  • Page 4 Configurator List Main window New configuration The function window allows to edit Filter Adding and editing programs Main part of the screen is taken by the Filter tab performs a similar function to Add or edit program displays a window 1) New configuration –...