Dc Current - Fluke 374 FC User Manual

Clamp meter
Hide thumbs Also See for 374 FC:
Table of Contents

Advertisement

Distance from
Optimum
A
B
C
Measurement uncertainty assumes centralized primary conductor at optimum position, no
external electrical or magnetic field, and within operating temperature range.

DC Current

Range
374 FC and 375 FC ........................... 600.0 A
376 FC ............................................... 999.9 A
Resolution ............................................... 0.1 A
Accuracy ................................................. 2 % ±5 digits
i2500-10 Flex
0.5 in (12.7 mm)
0.8 in (20.3 mm)
1.4 in (35.6 mm)
i2500-18 Flex
1.4 in (35.6 mm)
2.0 in (50.8 mm)
2.5 in (63.5 mm)
Clamp Meters
Specifications
Error
±0.5 %
±1.0 %
±2.0 %
27