Electrical connection

,
All electrical work must be
carried out by a suitably qualified
and competent person in
accordance with current local and
national safety regulations (BS 7671
in the UK).
– We recommend that connection be
made via a suitable plug and socket
which is easily accessible for
servicing and maintenance work
after the machine has been installed.
An electrical safety test must be
carried out after installation and after
any servicing work.
– For hard-wired machines, the
connection must be made via a
suitable mains switch with all-pole
isolation which when in the off
position ensures a 3 m gap between
all open contacts.
– For extra safety and protection we
recommend connecting the machine
by a 30 mA residual current device
(RCD).
– The mains connection cable may
only be replaced by an original Miele
spare part or an appropriate cable
with wire end ferrules.
– For technical data see data plate or
wiring diagram supplied with the
machine.
66
The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.
This machine can be converted to a
different type of power supply in
accordance with the conversion
diagram and wiring diagram supplied.
Equipotential bonding connection
There is a screw connection point
marked with the earth symbol (8) at the
back of the machine, to which
additional equipotential bonding can be
connected.
WARNING
THIS MACHINE
MUST BE EARTHED