Cleaning the spray arms

The spray arms can become blocked
and should therefore be checked every
day.
^ Use a sharp pointed object to push
particles into the spray arm jets, and
rinse well under running water.
Remove the spray arms as follows:
^ Take any baskets out of the wash
cabinet.
Spray arm on top basket or mobile unit
(if present):
^ Loosen the nut on the spray arm and
take the spray arm off.
Metal nuts have a left-hand thread.
Ceramic nuts have a right-hand
thread.
50
^ Unscrew the upper spray arm.
^ Loosen the knurled thumb nut to
unscrew the lower spray arm.
^ After cleaning the spray arms, fit or
screw them back into position.
After replacing the spray arms,
check that they rotate freely.