Follow these steps:
1) Turn off power to the system to be serviced.
2) Hook up the RecoverXL/XLT, the system to
be recovered, and the recovery tank as shown
in the diagram below.
3) Purge all hoses of non-condensables before
recovering refrigerant into recovery cylinder.
4) Open valves on the recovery tank.
5) Turn the selector valve to VAPOR position.
6) Turn the RecoverXL/XLT on.
7) Monitor the sight glass. When the passing
liquid is no longer visible through the sight
glass, the push-pull method of recovery is
complete.
8) Close the VAPOR valve on the recovery tank
Push-Pull Recovery Diagram
Recovering R-410A High Pressure Gas
IMPORTANT!!! Some equipment should not be
used with this refrigerant. Take time to read the
safety instructions that came with the device you
are servicing as well as any material that came with
your refrigerant.
WARNING!!! USE ONLY D.O.T. RECOVERY
CYLINDERS APPROVED FOR R-410A.
Overfilling the tank may cause it to rupture!
The RecoverXL/XLT will recover R-410A
provided the following instructions are followed:
1)
Set-up for recovery as per diagram on page 4
for normal recovery or page 6 for push-pull
recovery.
2)
Follow the operating procedures for your
6
and let the recovery continue.
9) Turn the selector valve clockwise to the
PURGE position and follow procedures for
purging the RecoverXL/XLT.
10) Turn the RecoverXL/XLT off.
11) Close LIQUID valve on recovery tank.
12) Reconnect the hoses per the procedure for the
RecoverXL/XLT instructions.
13) Rotate the selector valve to the VAPOR
position.
14) Continue recovery until the unit shuts off or
reaches the appropriate level of vacuum.
Note: See pages 3-4 for a detailed set of
instructions on Vapor Recovery.
model.
3)
Continue recovery until:
RecoverXL - suction gauge indicates the
appropriate level of vacuum.
RecoverXLT - Low Pressure Switch has
shut the unit off and lamp indicates Recovery
Complete.
4)
Turn system switch off.
5)
Purge the machine (see page 7 for more
details).
Technical Support: Call 800-769-8370 for
additional information.