  • Page 1 ® RecoverXLT Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual for 95760 and 95762 (For serial numbers 22120038 and higher) English, Spanish, French and German manuals available at: https://yellowjacket.com/product/recover-xlt/ PN 151204 RevB...
  • Page 2: Table Of Contents

    Use caution when connecting or disconnecting. Improper usage may result in ® 3) Ground all equipment. Plug the RecoverXLT refrigerant burns (frostbite). If a major leak into a properly grounded receptacle using the occurs, proceed immediately to a well ventilated appropriate plug.
  • Page 3: Care And Maintenance Auto Purge Instructions

    AWG (1.276 mm Care and Maintenance Auto Purge Instructions ® Purging or evacuating the RecoverXLT is one of After the unit stops, rotate the selector valve the simplest and most important functions. Reduce clockwise to OFF to equalize then to PURGE.
  • Page 4: Recoverxlt ® Operating Guide

    (Liquid Port) side of the system being serviced. ® 9. Turn the selector VALVE on the RecoverXLT Vapor recovery can be done by connecting to the to either the LIQUID or VAPOR position. system suction service port (low pressure) side of the system.
  • Page 5: Push-Pull Liquid Recovery

    1) Turn off power to the system to be serviced. auto purge feature makes the reconfiguration to ® 2) Hook up the RecoverXLT , the system to be vapor recovery easier and faster to do. recovered, and the recovery tank as shown in Some HVAC systems will not allow for the push- the diagram above.
  • Page 6: Recovery Tips & Techniques

    Suction means there is already liquid in the tank and ® over-filling can be a concern. Over-filling a Port of the RecoverXLT recovery cylinder can have disastrous results. ® 7) Protect the RecoverXLT by keeping the built-in suction filter IN THE MACHINE.
  • Page 7: Troubleshooting Guide

    15 inHg 15 inHg ® Other Refrigerants - The RecoverXLT is approved for use with other refrigerants which have not been certified for a particular recovery rate including: R-32, R-401A, R401B, R-402A, R-402B, R-404A, R-406A, R-407A, R-407B, R-407C, R-407D, R-408A, R-409A, R-411A and R-411B.
  • Page 8: Wiring Diagrams

    Technical Data, cont. Compressor: 1.25 HP 2 Cylinder Oil-less Reciprocating, Air Cooled Power Source: 100-240VAC 1ph 50/60Hz Amperage: 14.0 amps Motor Type: Variable Speed Brushless DC, 1200-3000 RPM Size: Height: 12.50” Width: 19.25” Depth: 12.50” Weight: 26.7 lbs. Wiring Diagrams...
  • Page 9: Replacement Parts

    REPLACEMENT PARTS ® RecoverXLT Parts Part # Description Part # Description 95156 12A Breaker 95575 XLT Compressor ONLY 95210 Strain Relief 95215 Power Cord 95573 Momentary Rocker Switch 95451 Gauge High 95217 Rubber Feet 95452 Gauge Low 95444 Case Front...
  • Page 10: Important Notice To Purchaser

    IMPORTANT NOTICE TO PURCHASER Check for damage immediately. Prior to assessing damage if the recovery system is re- ® ® shipment, all YELLOW JACKET RecoverXLT turned to the factory prepaid. Refrigerant Recovery Systems are completely Carton contents include: tested and inspected to assure compliance with Ritchie Engineering factory specifications.