49
Fault code
E008
E009
E010
E011
E012
E013
E014
E015
E018
E019
E020
If any problem occurs, please contact your supplier and provide the following information:
Inverter model:
Inverter serial number:
System version: version 1:
Fault code:
Fault description:

8. Contact

Solar Solutions GmbH
Schneckenhofstrasse 19
60596 Frankfurt am Main
Germany
www.aeg-industrialsolar.de
Technical Support:
Mail:
inverter-support@aeg-industrialsolar.de
Tel: +31 172 205 011
PD201709 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (4-10 kW) V.1-17 EN
Message
Instruction
IGBT drv
IGBT drive protection
Int Comm
Internal communication fault
Leek Fail
Huge leakage current
Relay Fault
Relay fault
Fan Fail
Fan fault
Eeprom
Memory error
Dc inject
High DC injection
OutputShort
Output short-circuit
Input OC
Input overcurrent
Incnst
Data consistency fault
PowerReversed
DC power reversed
Fault analysis
IGBT drive protection of the inverter
Master-slave DSP communication
disabled
Error of master-slave DSP check bit
Huge leakage current of the system or
inverter
Internal relay fault
Internal fan fault
Internal memory error
High DC injection during AC output
Output short-circuit
DC input overcurrent
Inconsistent grid voltage, frequency,
leakage current or AC/DC injection
DC power reversed