AEG AS-IC01-4000 Installation Instructions Manual page 46

Three-phase grid-tied solar inverter as-ic01 series and as-ic01-2 series (4 kw to 10 kw)
Table of Contents

Advertisement

45
Serial port to WIFI CLIENT (STA mode):
Serial port to WIFI AP:
Serial port configuration:
45
Current: display the current configuration;
Updated: display the current parameters to be modified.
Serial Configure: serial port configuration.
The format is as below: baud rate, parity check, data bits, stop bit, for example: "9600, 8 , n,1"
Serial Framing Length: framing length of the serial port
Serial Framing Timeout: framing time of the serial port
Network Mode: network mode, select Client, Server or none
Remote Server Domain/IP: The remote server domain name or IP address. For example, 192.168.200.1
Locale/Remote Port Number: Local or remote port number. Different network mode designates different parameters. In
the Client mode, it designates the remote port number and in Server mode, it designates the local port number.
Network Protocol: Network Protocol type, use tcp or udp protocol
Network Timeout: Network Timeout. In Server mode, there is no data during the timeout
PD201709 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (4-10 kW) V.1-17 EN