The inverter should be mounted in a vertical position of 90°to the horizontal line as shown in figure 9 (see 3.2.2
"Installation place").

3.3.1 Installation of three-phase inverters

Size of installation brackets:
AS-IC01-4000 / AS-IC01-4000-2 / AS-IC01-5000 /
AS-IC01-5000-2 / AS-IC01-6000-2 /
AS-IC01-8000-2 / AS-IC01-10000-2
Structure instruction of installation bracket:
Installation steps of three-phase inverter:
1.
If the installation brackets are still fastened to the inverter unit, remove the installation brackets from the
inverter unit and remove the M5 hex socket cap screws. Locate the installation holes with the installation
bracket;
2.
Use the expansion bolts to fix the installation bracket at the proper location of the walls;
3.
Lift the inverter to suspend it on the installation bracket through M8 hex socket cap screws;
4. Finally, fasten the M5 screws connecting the inverter with the bracket. For firm installation, the operators
cannot release the device until the inverter is installed on the bracket firmly.
PD201709 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (4-10 kW) V.1-17 EN
4-Ø8
Figure 10: Installation bracket
Model
Table 11: Size of installation brackets
No.
1
2
Table 12: Installation bracket structure
A
Installation hole
A (mm)
260*45
Installation hole Φ8
Structure instruction
Hexagon assembling bolt hole M4
18