For service issues, contact your installer. Värmebaronen AB retains the right to change the specification without prior notice, as part of its policy of continuous improvement and development. VÄRMEBARONEN VEDOLUX 37...
Page 3
Notes To be completed when the Vedolux 37 is installed! Serial number: ............................Installation date: ............................Installer: ............................Tel: ............................Other: ...................................................................................................................................................................... VÄRMEBARONEN VEDOLUX 37...
• accessory for pellet firing (cover plate with draught hatch for fan). operation. The flue ducts are round, which means there are no awkward corners when flue cleaning. Chimney The Vedolux 37 has a suction fan minimising the chimney require- ments of the boiler. VÄRMEBARONEN VEDOLUX 37...
2.5-3 h 41 mBar: °C 3,21 m³/h Firewood hatch w x h 290 x 235 mm Vedolux 37 with base frame and flue pipe straight up V37 Vedolux 37 with standard flue pipe 1310 1202 Hot water outlet, riser, G32.
Allow for 8 – 10 litres of tank volume per square metre of heated surface area. Chimney The schematic diagram below shows the Vedolux 37 with the Aqua- Height: min 3.5 metre...
Pellet burner The expansion vessel is best connected using 15 mm Cu The Vedolux 37 is primarily designed to be fired by firewood, but pipe, as shown in the diagram on the previous page. can also be modified for pellets using a pellet burner.
An thermostat limits the boiler’s working temperature. When the time set for the time relay, 30 minutes, is reached, the contact changes, which means that the fan and the charging pump for the accumulator system are controlled by the thermostat, 21. VÄRMEBARONEN VEDOLUX 37...
Firewood as a fuel Heat content Vedolux 37 has a ceramic grate and an afterburning chamber made The heat content is the amount of heat that can be extracted by the of high-temperature resistant stainless steel. The boiler works on the boiler and transferred to the boiler water.
Push down. The pin at gas temperature has fallen to below 120°C, the bottom of the ash the fan and charging pump to the accumula- hatch engages with the tor stop running. hole in the ash plate. VÄRMEBARONEN VEDOLUX 37...
• Clean the fan blades carefully so they keep their shape. You are tective layer of a couple of centimetres. recommended to use a paintbrush. Clean the chamber around the combustion tunnel. • Replace the fan and connect the cables. Close all hatches and dampers. VÄRMEBARONEN VEDOLUX 37...
– and therefore also the pressure – is higher in the sum- There is a risk of flames exiting through the hatch, mer than the winter. so take the greatest possible care! VÄRMEBARONEN VEDOLUX 37...
See the section about the “Expansion system” on page 5. the system heats up. Initial pressure in the expansion Check the pressure in the vessel; see the section about the “Expan- vessel too high/low. sion system” on page 5. VÄRMEBARONEN VEDOLUX 37...