    Contents Vedolux 37 11.03 Function..................2 Firewood.as.a.fuel...............8 Startup Technical.data................3 First burning cycle Installation..................4 Lighting – start General Lighting a fire with the gas lighter Chimney Adding wood Flue pipe Bypass damper Flue gas thermometer Controlling combustion...
  • Page 3 Notes Vedolux 37 11.03 To be completed when the Vedolux 37 is installed! Serial number: ............................Installation date: ............................Installer: ............................Tel: ............................Other: ...................................................................................................................................................................... Illustrations may differ from the actual product Allowing for printing errors and errors on proofs...
  • Page 4: Function

    Function Vedolux 37 11.03 Vedolux.37 Chimney • is a firewood boiler with a suction fan, designed for heating houses The Vedolux 3� has a suction fan minimising the chimney require- and smaller properties. ments of the boiler. • is environmentally-approved for firewood burning with an accumu- lator tank.
  • Page 5: Technical.data

    Technical.data Vedolux 37 11.03 Weight Firewood.hatch empty �05 lb w x h 11.4 x 9.3 in Chimney.requirement height filled with water 9�0 lb 11.5 ft Volume 32 gal flue duct recommended Ø 5.�1 in Pressure Design 25.6 in Test flue duct min Ø...
  • Page 6: Installation

    Installation Vedolux 37 11.03 Flue.pipe The installation must comply with the applicable The boiler is supplied with an angled regulations and standards. flue pipe – a flue pipe running up from the steel pipe is available as • The boiler must be installed in- Chimney an accessory.
  • Page 7: Function Of Accumulator Control

    Installation Vedolux 37 11.03 Function.of.accumulator.control Turbulators The accumulator control ensures that the boiler reaches a high The five turbulators are installed in the flue gas pipes as shown in working temperature before it starts charging the accumulator tank. the diagram. The purpose of the turbulators is to introduce turbu-...
  • Page 8: Electrical.connection

    Electrical.connection Vedolux 37 11.03 Electrical installation must be in accordance with the BLUE applicable regulations, under the supervision of an Supply YELLOW/GREEN authorised installer. BLACK Electrical.connection The boiler is connected directly to the mains. BLACK The electrical connections are at the rear of the boiler, in the form of...
  • Page 9: Checks

    Checks Vedolux 37 11.03 Checks After installation, check with the installer that the system is in perfect condition. Before putting the system into operation, check that: Ask the installer to demonstrate the settings and functions so you • the system is filled with water know how to operate and care for the system.
  • Page 10: Firewood.as.a.fuel

    Firewood.as.a.fuel Vedolux 37 11.03 20. Main switch. 21. Thermostat for fan and charging pump. 22. Fan start when the boiler is cold. 25. Overheating protection. 26. I ndicator showing triggered overheating protection. RESET ALARM 27. T hermometer, displays the boiler temperature. 28. P ressure gauge showing the water pressure in the MAIN SWITCH START STOP heating system. Startup RISK OF BURNS 1. the bypass damper must be in the closed position. Do not open the boiler hatches if the fan is not running 2.
  • Page 11: Flue.cleaning

    Cleaning Vedolux 37 11.03 When cleaning, do not leave any remains of wood or embers Ashes may contain embers for a long time after the burning on the grate. cycle, so keep them in a non-flammable container with a Disconnect the power supply to the boiler before cleaning.
  • Page 12: Operation.and.maintenance

    Operation.and.care Vedolux 37 11.03 Ceramic.-.combustion.tunnel Unvented.expansion.system The ceramic grate and combustion tunnel are wearing parts that The pressure in the unvented expansion vessel should be checked will have to be replaced over time. Wearing parts are not covered by at intervals of several years. The vessel must not be exposed to any any guarantee.
  • Page 13: Problems.burning.firewood

    Problems.burning.firewood Vedolux 37 11.03 The most common problems that occur when burning firewood are usually the result of the boiler failing to reach a high enough tem- perature so that the boiler never really gets going. Another common problem is that the heat is not transferred to the accumulator tanks even though the wood is burning well in the boiler.
  • Page 14: Component.specification

    Component.specification Vedolux 37 11.03 item prod.no. name qty. 12 00 1� Overheating protection 1-pole, alt. 110°C 12 00 53 Thermostat 1-pole 100-500°C 12 00 09 Handle thermostat 13 00 31 Switch 2-pole, auto-return 13 00 32 Switch 2-pole 16 00 01...
  • Page 16 Värmebaronen AB retains the right to change the specification of included components without prior notice, as part of its policy of continuous improvement and development. Värmebaronen AB +4644-226320 Arkelstorpsvägen 88 +4644-226358 291 94 Kristianstad www.varmebaronen.se Sweden info@varmebaronen.se...