2.4.3
This function records the maximum value during a mea-
surement.
• To activate, press the MAX button during the measure-
ment.
• To deactivate, press the MAX button again.
2.4.4
This function can be used to compare two voltage
measurements (e.g. to determine a voltage drop) or to
compensate for the resistance of the leads when making
low resistance measurements.
• To activate, press the ZERO button to enter the Zero
mode. The ZERO symbol will appear and Zero the
display. The reading is stored as a reference value for
subsequent measurements.
• To exit the Zero mode, press the ZERO button again.
2.4.5
The Model 565 will automatically shut down if there is no
activity for approximately 10 minutes .
• To disable the Auto-OFF function, turn the rotary
switch to OFF.
• Press and hold down the ZERO button and set the
rotary switch to any position other than OFF.
• The
is deactivated.
1.800.561.8187
Clamp-on Meter Model 565
MAX Button
Zero (Relative) Button
Auto-OFF
symbol disappears and the Auto-OFF feature