Field settings table
Breadcrumb
Field code
Setting name
A.8
[9-00]
What is the maximum desired LWT for main zone in heating?
A.8
[9-01]
What is the minimum desired LWT for main zone in heating?
A.8
[9-02]
What is the maximum desired LWT for main zone in cooling?
A.8
[9-03]
What is the minimum desired LWT for main zone in cooling?
A.8
[9-04]
Leaving water temperature overshoot temperature.
A.8
[9-05]
--
A.8
[9-06]
--
A.8
[9-07]
--
A.8
[9-08]
--
A.8
[9-09]
What is the desired delta T in heating?
A.8
[9-0A]
What is the desired delta T in cooling?
A.8
[9-0B]
What emitter type is connected to the main LWT zone?
A.8
[9-0C]
Room temperature hysteresis.
A.8
[9-0D]
Pump speed limitation
A.8
[9-0E]
--
A.8
[A-00]
--
A.8
[A-01]
--
A.8
[A-02]
--
A.8
[A-03]
--
A.8
[A-04]
--
A.8
[B-00]
--
A.8
[B-01]
--
A.8
[B-02]
--
A.8
[B-03]
--
A.8
[B-04]
--
A.8
[C-00]
--
A.8
[C-01]
--
A.8
[C-02]
Is an external backup heat source connected?
A.8
[C-03]
Bivalent activation temperature.
A.8
[C-04]
Bivalent hysteresis temperature.
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
--
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
--
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
A.8
[D-01]
Forced off contact type
A.8
[D-02]
--
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
Is the option box used for PCC ?
A.8
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
A.8
[D-07]
--
A.8
[D-08]
Is an external kWh meter used for power measurement?
A.8
[D-09]
Is an external kWh meter used for power measurement?
A.8
[D-0A]
--
A.8
[D-0B]
--
A.8
[D-0C]
What is the high electricity price (Do not use)
A.8
[D-0D]
What is the medium electricity price (Do not use)
A.8
[D-0E]
What is the low electricity price (Do not use)
4P478618-1B - 2017.06
Range, step
Default value
R/W
37~55°C, step: 1°C
55°C
R/W
15~37°C, step: 1°C
25°C
R/W
18~22°C, step: 1°C
22°C
R/W
5~18°C, step: 1°C
5°C
R/W
1~4°C, step: 1°C
1°C
25
55
5
22
R/W
3~10°C, step: 1°C
5°C
R/W
3~10°C, step: 1°C
5°C
R/W
0: Quick
1: Slow
R/W
1~6°C, step: 0,5°C
1 °C
R/W
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
6
0
0
0
0
0
0
0
0
0
0
0
0
R/W
0: No
1: Bivalent
2: -
3: -
R/W
-25~25°C, step: 1°C
0°C
R/W
2~10°C, step: 1°C
3°C
R/W
1: Thermo ON/OFF
2: C/H request
1
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
0
R/W
0~7
0
R/W
0~7
0
R/W
0~7
0
R/W
0~3
0: None
2: BUH only
3: All heaters
R/W
0~3
0: No
1: Open tariff
2: Closed tariff
0
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
R/W
0: No
1: Yes
R/W
0: Forced off
1: As normal
0
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0
2
R/W
0~49
0
R/W
0~49
0
R/W
0~49
0
Installer setting at variance with
default value
Date
Value
(*1) EWYQ*_(*2) EWAQ*